DINAMIC 1.1
• Repair the possible obstruction of the blower or of the electro; if the error persists, replace
the blower or the electro.
(If the error persists, contact an Authorised Technician).
• Check the equipment load (the operating pressure of the equipment should not exceed 3
bars); if the pressure is not correct, recover gas, empty the circuit for at least 30 minutes
and introduce 300 g of R134-a gas in the circuit.
• Replace the compressor
• Replace the control module
(If the error persists, contact an Authorised Technician).
• This may be due to long periods of operation. Turn of the equipment for at least 1
hour.
(If the error persists, contact an Authorised Technician).
• Check and correct possible poor contacts in terminals or cables of the antifreeze
sensor.
• Connect or replace the antifreeze sensor.
(If the error persists, contact an Authorised Technician).
Solution
13
Air conditioning for vehicles