8 en | Cable Requirements
4
Cable Requirements
The specifications for the UHI-SBG-0 Series may vary depending on the model that you are
operating. Refer to the following tables for more information.
Video Transmission (coaxial)
Input Power Cord - North American
Input Power Cord - European
September 15, 2006 | F01U032279_01
Type
Specification
Cable Type
RG-59/U for runs < 300 m (1000 ft)
RG-11/U for runs < 600 m (2000 ft)
Cable Size
Outside diameter between 4.6 mm
(0.181 in.) -7.9 mm (0.312 in.)
Cable Shape
Round
Shield
> 93% Braided copper shield
Center Conductor
Stranded or solid copper center
DC Resistance
< 15 Ohm/1000 (RG-59/U)
< 6 Ohm/1000 (RG-11/U)
Cable Impedance
75 Ohm
Agency Rating
UL
Environmental
Outdoor rated
Temperature Rating > 80°C
Sources
Belden 9259 H05RN-F 3 G 1.00
Type
Specification
Cable Type
120 V 3x 18 AWG
Cable Size
Outside diameter between
4.6 mm (0.18 in.) -7.9 mm (0.31 in.)
Cable Shape
Round
Conductors
3-conductor version
Agency Rating
UL/C.S.A., UL VW-1
Environmental
Outdoor rated
Temperature Rating 105°C
Voltage Rating
300 V
Type
Specification
Cable Type
H05RN-F 3 G 0.75 and H05RN-F 3 G 1.00
Cable Size
Outside diameter between
4.6 mm (0.18 in.) -7.9 mm (0.31 in.)
Cable Shape
Round
Conductors
3-Conductor version
Agency Rating
VDE
Environmental
Outdoor rated
Installation Manual
UHI-SBG-0 Series
Bosch Security Systems, Inc.