12
UK
PROGRAMMING FUNCTIONS (DIP SWITCH)
ON
DIP1
OFF
ON
DIP2
OFF
ON
DIP3
OFF
ON
DIP4
OFF
ON
DIP5
OFF
ON
DIP6
OFF
ON
DIP7
OFF
ON
DIP8
OFF
ON
DIP9
OFF
ON
DIP10
OFF
In the event of a system with only one motor and using the limit switches, the dip switches 4, 5,
6 and 7 must all be set to OFF, while if using only one type of limit switch, e.g. Fa1 and/or Fa2,
enable (OFF position) only the corresponding dip switch.
When the photocell is intercepted, both during opening and closing, the gate motion is
locked until the photocell is freed. Subsequently, there is always an opening phase.
The photocell stops and immediately inverts the motion of the gate during the closing
phase, while during opening it is uninfluential.
Enables the CONDOMINIUM function, i.e. one START command opens the gate, and no
other START commands are accepted during opening. During PAUSE, one START
command reloads the pause time. During closing, one START command reopens the
gate.Reclosing occurs only in automatic mode after the pause time, also when V4 is on
minimum.
Enables the STEP-BY-STEP functions (one START command OPENS, a second
command STOPS, a third command CLOSES the gate) or STEP-BY-STEP with
AUTOMATIC RECLOSING depending on how trimmer V4 is positioned:
• If turned completely anticlockwise = STEP-BY-STEP
• If turned clockwise = STEP-BY-STEP with RECLOSING i.e. after the pause time it
recloses automatically. To close with the remote control during the pause, two start
commands must be given (the first command sets the gate to STOP).
Enables the WATER HAMMER function - exercises a brief thrust during closing before
opening, facilitating release of the electric lock (if the limit switches are used, this
function is disabled)
Disables the WATER HAMMER function
Cuts out limit switch input - opens motor 1
Enables the opening limit switch input motor 1
Cuts out limit switch input - closes motor 1
Enables the closing limit switch input motor 1
Cuts out limit switch input - opens motor 2
Enables the opening limit switch input motor 2
Cuts out limit switch input - closes motor 2
Enables the closing limit switch input motor 2
Cuts out photocell input
Enables the photocell input
The outputs 7-8 of the terminal board are used to control a FLASHLIGHT equipped
with its own flashing circuit (code 70106)
The outputs 7-8 of the terminal board become outputs for the COURTESY LIGHT and
remain active for 3 minutes after the run time (max. 100W). In this mode the terminals
28-29 can be used to connect a flashlight without flashing circuit.(code 70107)
NOT USED
NOT USED
F4 PLUS