AERMEC ECA Serie Manual De Instalación página 21

Unidades internas “cassette” para instalaciones de acondicionadores bombas de calor del tipo split
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

TAV 2 REFRIGERANT LINES
R410A - Mod. CS e CS-H
Liquid line
Tightening torque
Gas line
Tightening torque
L = Maximum refrigerant line lenght
H = Max. difference of level between indoor and outdoor units
Refrigerant recharge
For line lenght longer than
R407C - Mod. CXA-T
Liquid line
Tightening torque
Gas line
Tightening torque
L = Maximum refrigerant line lenght
H = Max. difference of level between indoor and outdoor units
Refrigerant recharge
For line lenght longer than
ECA 120 - 180 - 240
CONNECTIONS:
SC
= Condensate drain (male Ø 16 mm)
(E)
= Wiring diagrams
ECA 120
6,35x(≥0,8) (1/4")
14-18 [N*m]
9,52x(≥0,8) (3/8")
30-40 [N*m]
15 [m]
7 [m]
15 [g/m]
7,5 [m]
Liquid line
SC
ECA180
ECA 240
6,35x(≥0,8) (1/4")
6,35x(≥0,8) (1/4")
14-18 [N*m]
14-18 [N*m]
12,7x(≥0,8) (1/2")
12,7x(≥0,8) (1/2")
50-62 [N*m]
50-62 [N*m]
15 [m]
10 [m]
15 [g/m]
15 [g/m]
7,5 [m]
7,5 [m]
ECA180
ECA 240
6,35x(≥0,8) (1/4")
6,35x(≥0,8) (1/4")
15 - 20 [N*m]
15 - 20 [N*m]
12,7x(≥0,8) (1/2")
15,88x(≥0,8) (5/8")
49 - 59 [N*m]
62 - 76 [N*m]
15 [m]
7 [m]
20 [g/m]
20 [g/m]
10 [m]
Gas line
(E) IN
GB
15 [m]
10 [m]
15 [m]
7 [m]
10 [m]
Fig. 1
21

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Eca 120Eca180Eca 240

Tabla de contenido