I Setting the Fan Speed
• Press 4 to select:-
FAN
– Low Fan Speed
FAN
– Medium Fan Speed
FAN
– High Fan Speed
AUTO
FAN
–
Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.
I Setting the Vertical Airflow Direction
• Press 5 or 6 to select:-
Cooling Model
COOL / DRY Operation
FAN Operation
AUTO
AUTO
36°
61°
Move up/down
Swing up/down
Automatically
Automatically
MANUAL
MANUAL
Five stages of adjustment
Five stages of adjustment
can be made between
can be made between
0 ~ 61 angle.
14 ~ 36 angle.
Heat Pump Model
COOL / DRY Operation
HEAT Operation
AUTO
AUTO
– When the discharge air
temperature is low such
as at the start of heating
operation, the air blows
36°
in a horizontal direction.
As the temperature
rises, the hot air blows
Swing up/down
in a downward direction.
Automatically
– To stop this operation,
press MANUAL.
MANUAL
MANUAL
Five stages of adjustment
Five stages of adjustment
can be made between
can be made between
14 ~ 36 angle.
0 ~ 61 angle.
I Setting the Horizontal Airflow Direction
• Adjust it manually
G Use this air conditioner under the following
conditions:
Cooling Model
Indoor
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT
WBT
Maximum Temperature
89.6
73.4
60.8
51.8
Minimum Temperature
Heat Pump Model
Indoor
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
DBT
WBT
Maximum Temperature-Cooling
89.6
73.4
(Maximum Temperature-Heating)
(86)
(–)
Minimum Temperature-Cooling
60.8
51.8
(Minimum Temperature-Heating)
(60.8)
(–)
G Notes
•
If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.5 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.
•
If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.
G Operation Details
COOL – Cooling Operation
•
To set the room temperature at your preference
cooling comfort.
AUTO – Automatic Operation
•
Sense indoor temperature to select the optimum
mode.
•
Temperature is not displayed on the remote control
during AUTO operation.
DRY – Soft Dry Operation
•
A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
•
During Soft Dry operation, the indoor fan operates at
(Unit in °F)
Low fan speed.
Outdoor
HEAT – Heating Operation
DBT
WBT
(for Heat Pump Model only)
•
Heat is obtained from outdoor air to warm up the
109.4
78.8
room. When the outdoor ambient air temperature
60.8
51.8
falls, the heating capacity of the unit might be
reduced.
•
Defrosting Operation
Depending on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.
(Unit in °F)
Outdoor
FAN – Air Circulation Operation
(for Cooling Model only)
DBT
WBT
•
When the room temperature reaches the set
109.4
78.8
temperature, operation commences at Low airflow
(75.2)
(64.4)
volume. It stops when the room temperature drops to
4°F below the set temperature.
60.8
51.8
(It is useful when using a heater).
(23)
(21.2)
•
Hi fan speed will not operate when using the air
circulation Fan mode.
6