9 IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
If required by the National Electrical
Code (or Canadian Electrical Code), this
appliance must be installed on a separate
branch circuit.
The circuit breaker should have a contact
separation of at least 3 mm on all poles.
Be sure your appliance is properly
installed and grounded by a qualified
technician. Installation, electrical
connections and grounding must comply
with all applicable codes.
Before installing, turn power OFF at the
service panel. Lock service panel to
prevent power from being turned ON
accidentally.
9
WARNING
IMPROPER GROUNDING CAN RESULT IN A
RISK OF ELECTRIC SHOCK!
Consult a qualified electrician if the
grounding instructions are not
completely understood, or if doubt
exists as to whether the appliance
is properly grounded. DO NOT USE
AN EXTENSION CORD.
Related Equipment Safety
The appliance should only be used if
installed by a qualified technician in
accordance with these installation
instructions. The manufacturer is not
responsible for any damage resulting
from incorrect installation.
Never modify or alter the construction of
the appliance. For example, do not
4
remove leveling legs, panels, wire covers
or anti-tip brackets/screws.
To eliminate the risk of burns or fire by
reaching over heated surface units,
cabinet storage space located above the
surface units should be avoided. If
cabinet storage is to be provided, the risk
can be reduced by installing a hood that
projects horizontally a minimum of 5
inches (127 mm) beyond the bottom of
the cabinet.
Verify that cabinets above the cooktop are
a maximum of 13" (330 mm) deep.
DO NOT install refrigerators,
dishwashers, ovens (without ventilation),
or washing machines below the cooktop.
Note: We strongly recommend the
installation of a ventilation system with
this appliance.