Technical Characteristics; Diagnostics Led - tau K100M Guía Para La Instalación

Ocultar thumbs Ver también para K100M:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MANUFACTURER'S DECLARATION OF INCORPORATION
(in accordance with European Directive 2006/42/EC App. II.B)
Manufacturer:
Address:
Declares under its sole responsibility, that the product:
designed for automatic movement of:
for use in a:
complete with:
Model:
Type:
Serial number:
Commercial name:
Has been produced for incorporation on an access point (swing gate) of for assembly with other devices used to move such an access point, to constitute a machine
in accordance with the Machinery Directive 2006/42/EC.
Also declares that this product complies with the essential safety requirements of the following EEC directives:
-
2014/35/EU Low Voltage Directive
-
2014/30/EU Electromagnetic Compatibility Directive
and, where required, with the Directive:
-
2014/53/EU Radio equipment and telecommunications terminal equipment
Also declares that it is not permitted to start up the machine until the machine in which it is incorporated or of which it will be a component has been identified
with the relative declaration of conformity with the provisions of Directive 2006/42/EC.
The following standards and technical specifications are applied:
EN 61000-6-2;
EN 61000-6-3;
EN 60335-1;
ETSI EN 301 489-1 V1.9.2;
EN 60335-2-103;
The manufacturer undertakes to provide, on sufficiently motivated request by national authorities, all information pertinent to the quasi-machinery.
Sandrigo, 08/11/2016
Name and address of person authorised to draw up all pertinent technical documentation:
Loris Virgilio Danieli - via E. Fermi, 43 - 36066 Sandrigo (Vi) Italy
ON
1
2
3
4
5
6
M3
M2
Dip-switches
FR
-
+
SENS
-
+
TCA
-
+
SM
DL3
PHOTO
DL4
CLOSE LIMIT SWITCH
DL5
OPEN LIMIT SWITCH
DL6
STOP
K100M
DL2
OPEN/CLOSE
DL1
RADIO CONTROLS
TAU S.r.l.
Via E. Fermi, 43
36066 Sandrigo (Vi)
ITALY
Electronic control unit
Swing gate
General environment
Radioreceiver
K100M
K100M
see silver label
Control panel for T-ONE5E gearmotor
ETSI EN 301 489-3 V1.6.1;
EN 300 220-2 V2.4.1;
Legal Representative
_________________________________________
Loris Virgilio Danieli
Antenna
TX
Photocells
14
1 2
13
1
2
3
4
5
6
Photocell - 24 V AC
12
0 V AC
11
FR
Common
10
Photocell (N.C.)
SENS
9
Stop
8
TCA
DL3
Open/Close
7
RESET
DL4
F2
DL5
OP/CL
DL6
F1
Flashing
DL2
RADIO
light
4
DL1
230 V AC
max. 50W
3
2
Phase
1
Neutral
K100M
Control panel for T-ONE5E gearmotor
GB - Translation of original instructions
D_MNL0K100M 05-05-2017 - Rev.08
WARNING!
Attention: This product may only be installed from professional installers. Only qualified and trained electricians may connect, programme and
service the controls.
No information given in this manual can be considered as being of interest to end users.
This manual is enclosed with control unit K100M and may therefore not be used for different products!
Important information:
Disconnect electric power to the system before making maintenance, repairs or removing covers
The K100M control unit has been designed to control a electromechanical sliding door operator.
Any other use is considered improper and is consequently forbidden by current laws.
Read all instructions carefully and completely before attempting to install and use this automatic gate operator!
INSTALLATION
Make sure the gate has been properly installed and slides freely in both directions. Repair or replace all worn or damaged gate hardware prior
to installation. A freely moving gate will require less force to operate and will enhance the performance of the operator and safety devices used
with the system.
Also check that the gate operator assembly has been installed according to the instructions.
WARNING: The automatic gate operator must be grounded - All Federal, State and local safety codes must be observed.
ATTENTION:
-
do not use solid wire, use only multi threaded wire
-
do not reuse pre-existing electric wire.
IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED THE "MANUFACTURER" SHALL IN NO EVENT BE LIABLE FOR DIRECT, INDIRECT, INCI-
DENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES OR LOSS OF PROFITS WHETHER BASED IN CONTRACT TORT OR ANY OTHER LEGAL
THEORY DURING THE COURSE OF THE WARRANTY OR AT ANY TIME THEREAFTER.
CONTROL PANEL FOR ONE 230 V AC MOTOR
MICROPROCESSOR-CONTROLLED LOGIC
STATUS LEDS
LINE FUSE
BUILT-IN FLASHING LIGHT CIRCUIT
BUILT-IN 433.92 MHz RADIO RECEIVER
MAX. OPERATING TIME 96"
AUTOMATIC 50 / 60 HZ FREQUENCY DETECTION
ADJUSTABLE SOFT-STOP
RX
AMPEROMETRIC OBSTACLE DETECTION
1 2 3 4 5
TESTING
Once the connection has been completed:
 All the green LEDs must be ON (each of them corresponds to a Normally Closed input). They will turn OFF when the controls to which they are as-
sociated are operated.
 The opening control red LED must be switched OFF (corresponding to a Normally Open input), it comes ON only when the control it is associated with
is involved; the DL1 red LED must be steady ON.

TECHNICAL CHARACTERISTICS

Power input – control board
Nominal power
230 V AC Input protection fast blow fuse (F1 - 5x20)
Power input – motors
Power input – auxiliary circuits
24 V AC Input (auxiliary circuits) fast blow fuse (F2 - 5x20)
Working temperature
Protection degree

DIAGNOSTICS LED

DL1 (RADIO CONTROLS) / RED
DL2 (OPEN/CLOSE) / RED
DL3 (PHOTO) / GREEN
DL4 (CLOSE LIMIT SWITCH) / GREEN
DL5 (OPEN LIMIT SWITCH) / GREEN
DL6 (STOP) / GREEN
230 V AC - 50-60 Hz
-20°C ÷ +55°C
ERROR message / PROGRAMMING of transmitters
OPEN / CLOSE pushbutton activated
PHOTOCELL activated
CLOSING LIMIT SWITCH activated
OPENING LIMIT SWITCH activated
STOP pushbutton activated
INSTALLATION GUIDE
English
400 W
F 3,15 A
230 V AC
24 V AC
F 500 mA
IP 44

Publicidad

Tabla de contenido
loading

Tabla de contenido