Cabinet Dimensions - Dacor DOP36M96GL Instrucciones De Instalación

Ocultar thumbs Ver también para DOP36M96GL:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation requirements

Cabinet dimensions

• All maximum and minimum dimensions and clearances shown in the diagrams below
must be maintained for safe operation.
• Verify that the range installation site is away from any type of draft.
• To reduce risk of fire and personal injury, cabinets should not be installed above the
range. If such cabinets are unavoidable, install a range hood that projects 5" beyond
the front of those cabinets.
Range Model
DOP36M96*
* Recommended ** Minimum *** Maximum
Standard Cutout with Range Hood
13" (33.0 cm)
max.
5
30" (76.2 cm)
min.
18" (45.7 cm)
4, 5
Grate
level
Note 2
37 1/2"
(95.3 cm)
max.
26
English
Install_NX9900R_PRORANGE_DOP36M96_DA_DG68-01106C-02_EN+MES+CFR.indb 26
CUTOUT DIMENSIONS
A
42" (106.7 cm)*
36" (91.4 cm)**
A
Non-combustible
surface along back wall
recommended
Top of
finished
counter
1
B
Suggested
location of
utilities
3
36 1/8" (91.7 cm)***
1
Vertical from range grate
level to combustible overhead
surface; if installing an
overhead vent hood, also
check hood specifications for
minimum required clearances.
2
Cabinet/countertop depth
is at discretion of customer
but cabinet face MUST NOT
protrude further than rear
of front panel, see product
10" (25.4 cm) min.
to combustible side
dimensions.
walls above the range
(both sides)
3
Consult local code for exact
location requirements.
4
Vertical from grate level to
combustible surface.
5
This specification does not
apply for cabinets more than
a horizontal distance of 10"
(25.4 cm) from the edge of the
range.
B
36" (91.4 cm)**
2019-08-13
6:30:51

Publicidad

Tabla de contenido
loading

Tabla de contenido