Electrical requirements
• Failure to follow these instructions can result in death, fire, or electrical shock.
WARNING
• It is the owner's responsibility to make sure that the electrical service meets electrical
requirements and that he electrical outlet has been properly installed by a licensed
electrician.
• To reduce the risk of fire, electric shock, or personal injury:
All range
• Do not use an extension cord or adapter plug with this range.
• This range must be properly grounded.
• Check with a qualified electrician if you are in doubt as to whether your range is
properly grounded and polarized.
• Do not modify the range power plug. If it does not fit the outlet, have a proper outlet
installed by a qualified electrician.
• All wiring and grounding must comply with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA No. 70 – Latest Revision (US), or
the Canadian Electrical Code CSA C22.1 – Latest Revisions and local codes.
• The wiring diagram is located on the back of the range.
• The range's electronic ignition system will not operate if the outlet is not properly
polarized.
• A dedicated circuit breaker is recommended.
• This table gives the minimum recommended dedicated-circuit protection.
KW Rating (120 V)
Install_NX9900R_PRORANGE_DOP36M96_DA_DG68-01106C-02_EN+MES+CFR.indb 31
0 - 7.2 KW
Recommended Circuit Size (Dedicated)
10 Amp
English 31