GB
U S E R G U I D E
3. ADJUSTMENTS
Two push buttons, P1 and P2, allow you to adjust the chlo-
rine production (P2 increases production and P1 reduces
it).
4. ALARMS
The red LEDs indicate the following alarms:
LED9: EXCESS SALT
Causes:
The cell is dirty.
More salt than necessary has been added.
LED8: TOO LITTLE SALT
Causes:
The cell is dirty.
The pool has been filled with fresh water.
The pool water needs more salt.
LED7 and buzzer alarm.
LED7 flashes, indicating that gas has accumulated in the
electrolysis cell. The green LEDs column flashes, indicating
that the equipment has cut off the current to the cell.
-"ABSENCE OF WATER FLOW":
Causes:
The pump has stopped.
Excess hydrogen gas (highly flammable) in the electrolytic
cell, which causes the pump to stop.
There is an air pocket in the cell.
Incorrect connection of the sensor cable.
The sensor cable is broken.
The cell sensor is dirty.
The cell sensor is broken.
The equipment is damaged.
12
The green LEDs (LED1 to LED5) indicate the chlorine pro-
duction: 0%, 25%, 50%, 75% and 100% of the total.
The adjustment is maintained, even when the equipment
is disconnected.
Corrective action:
Remove the cell and clean it.
Dilute by adding more water.
Corrective action:
Clean the cell.
Add salt to the water.
Add salt to the water.
Corrective action:
Restore the water circulation. Once the water flow has
been restored, the alarm will automatically be reset.
Bleed the pipe to eliminate the accumulated gas.
Bleed the pipe to eliminate the air pocket.
Check that the sensor cable (white) is properly
connected.
Check the cable and change it.
Remove the cell and clean it as explained in the guide.
Change the cell.
Contact ESPA technical assistance service.