Installation • Instalación
Installation • Instalação
20
english
1. Feed pipe and fitting at least ¾"!
(internal diameter > 18 mm / 0,71 inch)
2. No filters in feed line
3. Slope in feed line > 1%!
4. Only use ball valves with full open
port!
5. Pressure: min. 0.8 bar or 1.2 bar (11.6
psig or 17.4 psig)!
(check type plate for correct pres-
sure)
6. Check valve
It is essential to observe the direction
of installation. The check valve must
open towards the outflow direction.
7. Short pressure hose!
8. For each yard of rising slope in the
outlet line, the required minimum
pressure will increase by 0.1 bar (0.14
psig).
The rise of the outlet line must not
exceed 5 m (17 feet)!
9. Collecting line min. 1" with 1% slope
10. In the case of inflow problems, install
venting line.
BEKOMAT 14 CV, 14 CO CV