Symmons SCOT SLC-6000 Serie Manual De Funcionamiento Y Mantenimiento página 4

Grifo dosificador para lavabo
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation (adjustments)
1) Faucet is factory set to shortest cycle
time with 7 cycle timing washers (C).
To increase time, loosen set screw (B),
remove handle (A) and remove
one or more of the washers.
To reduce time, add washers.
Reassemble faucet reversing above
procedure.
A
2
C
3
Note: When setting MAXIMUM cycle
time, you MUST maintain at least 5
timing washers (C) so as not to exceed
.25 gal/cyl at 60 psi (per ASME A112.18.1)
Maintenance
1) Loosen set screw (B), remove
handle (A) and remove cycle timing
washers (C).
A
2
C
3
2) To limit temperature loosen set
screw (B), remove handle (A), loosen
nut (D) and turn cartridge stem (H)
to desired maximum temperature
(110°F recommended). Turn limit
stop washer (E) clockwise until a
positive stop is reached against
back of faucet. Reassemble faucet
reversing above procedure.
B
4
Note: Faucet will operate from the
full cold position to the maximum hot
temperature that has been set.
2) Remove nut (D), limit stop washers (E)
& (F) and cartridge housing (G).
B
B
A
2
C
5
3
H
D
E
6
D
1
E
F
2
G
3
4
3) For reverse operation (in back to
back installations or when hot supply
is on the right) loosen set screw (B),
remove handle (A), nut (D) and limit
stop washers (E) & (F). Turn cartridge
stem (H) 180° so green marking*
is facing toward front of faucet.
Adjust temperature limit (see step 2).
Reassemble faucet, reversing the
above procedure.
A
2
C
3
D
4
E
5
H
3) Remove cartridge (H) and inspect for
debris. Replace cartridge if neces-
sary. Reassemble faucet reversing
procedure outlined in Steps 1 & 2.
H
B
*
F

Publicidad