Troubleshooting

If other trouble occurs

Symptom
Nothing displays on
the Operation Panel
even though the
Power Switch is ON.
No copy is produced
when [Start] is
pressed.
Nothing appears on
the copy.
A light copy is
produced.
9-2
Check the following items when trouble occurs. If the problem is not
resolved after checking these items, contact your service representative.
Items to Check
Check to make sure the copier is
plugged into the outlet.
Check to see if something has
been displayed on the Operation
Panel.
Check to see that the original
has been set properly.
Check to see if the copier is in
Auto Exposure Mode.
Check to see if the copier is in
Manual Exposure Mode.
Check to see if the toner in the
toner container is canted.
Check to see if the Add Toner
Indicator is lit.
Check to see if the paper is
damp or not.
Check to see if the electrical
charge section is dirty or not.
Corrective Procedure
Plug the copier power cord into
the outlet.
Check the corrective procedure
for the error display and carry it
out.
Place the original face down on
the platen and adjust the Original
Size Indicator Plate to match its
size.
Place the original face up when
setting it in the optional
Document Processor.
When the exposure is to be
changed overall, perform out the
"Auto Exposure Adjustment".
Use Exposure Adjustment to set
the proper exposure.
When the exposure is to be
changed overall, perform the
Manual Exposure Adjustment in
each original mode.
Shake the Toner Container left
and right for approximately 10
times.
Replace the Toner Container.
Replace the paper with new
paper.
Open the front cover and use the
Cleaning Rod to clean the
electrical charge section.
Reference
Page
9-5
3-2
7-3
5-11
3-3
3-3
8-8
8-5
8-7