2. OPERATION AND USE
- A short press on the button switches the light on or off. A turn of
the control key controls the light intensity.
- The dimmer must be mounted into a flush mounting box with a
min. recess depth of 40mm. The central plate with button and
flush surround plate are to be ordered separately. They must be
mounted before switching on the power supply. Use without plates
is prohibited.
- Due to circular impulses of the power station, the light sources can
briefly blink.
- Not all types of dimmers are suitable for all types of loads. For the
accepted load per dimmer, see 'technical data' of the dimmers.
symbol of the connectable loads: R=ohmic; L=inductive;
R,L,C
C=capacitive.
- Only use original replacement fuses with Niko reference number.
When using other fuses, the device can be damaged, the safety
is not guaranteed and the factory guarantee expires.
- Phase control (09-013, 09-014 & 09-016) of the mains voltage
brings about current or power components with higher frequencies.
EN
45