Indicator Lights - Klarstein Frostica Manual Del Usuario

Máquina de hielo en escamas
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Problem
The indicator light "FAULT"
illuminates.

Indicator lights

Indicator
No indicator is on.
The "RUN" indicator light is on.
The "ICE FULL" indicator light is on.
The "WATER LOW" indicator light flashes
every second.
The indicator light "WATER LOW" lights
up permanently.
Possible Cause
1.) Ice has jammed in the
appliance and has not
fallen into the ice storage
container.
2.) The water tank is not in
the correct position.
Possible Cause
Connect the appliance to the power
supply. The appliance is currently in self-
analysis mode.
The appliance is in normal operation
mode.
The storage container is full or the tempe-
rature is less than 5 °C.
There is no water in the appliance. As
soon as the appliance is supplied with
water again, it functions automatically.
There is no water in the appliance. Reset
the appliance as soon as water is added
again.
Suggested Solution
1.) Check that the solenoid
valve is open. Replace it
if not.
2.)
• Check whether the
switch (SQ1) can
receive information
from the rotation of
the unbalance wheel.
• Check whether the
rotating motor and
the unbalance wheel
spin.
• Check whether
the motor gear is
damaged by turning
the unbalance wheel
by hand.