Meccanica Fadini Elpro 12 PLUS Folleto De Instrucciones página 4

Monofasico para verjas deslizantes nyota 115
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

12
GB
3
28
PULIN 3
L2
L3
L4
L5
L6
TRIMMER
-
+
-
+
-
R65
R64
R63
The electronic control panel Elpro 12 Plus, new generation, is designed to operate the sliding gate operator Nyota 115. Power supply is 230V 50Hz single-phase. Built in
full compliance with BT 93/68/CE Low Voltage and EMC 93/68/CE Electro-Magnetic Compatibility Regulations. Fitting operations are recommended by a qualified technician
in conformity to the existing safety standards.
The manufacturing company declines any responsability for incorrect handling and application; also, it reserves the right to change or update the control panel any time.
PLEASE NOTE:
- The control panel must be installed in a sheltered, dry place, inside the box provided with it.
- Fit the mains to the control panel with a 0.03A high performance circuit breaker.
2
- Use 1.5mm
section wires for voltage supply, electric motor and flashing lamp.
Maximum recommended distance 50m.
2
Use 1mm
section wires for limit switches, photocells, push-buttons/key-switch and accessories.
- Bridge terminals 1 and 2 if no photocells are required.
- Bridge terminals 3 and 6 if no key- or push-button switches are required.
N.W: To fit extra accessories such as lights, CCTV etc. use only solid state relays to prevent damages to the microprocessor.
Dip-Switch:
1= ON. Photocells. Stop while opening
2= ON. Radio. No reversing while opening
3= ON. Automatic closing
4= ON. Preflashing activated
5= ON. Radio. Step by step. Stop in between
6= ON. Dead Man Control (Dip 4=OFF and Dip 3=OFF)
7= ON. No lamp on during dwell time
8= OFF. No function
Led Status Indication:
L1= 230V 50Hz power supply. Alight
L2= Photocells, if obstructed light goes off
L3= Open. Alight whenever an Open pulse is given
L4= Close. Alight whenever a Close pulse is given
L5= Stop. It goes off on pulsing Stop
L6= Radio. It goes on by pressing a transmitter button
L7= Gate Status; it flashes on gate opening
L8= Limit switch Close; off when gate is closed
L9= Limit switch Open; off when gate is open
4086
Drwg. No.
PLUS
26
27
L9
L7
L8
DIP-SWITCH
1
2 3
4 5 6 7 8
+
-
+
R62
1
RADIO
PLUG-IN
CARD
CONNECTOR
L1
ON
OFF
1
2
3
4
5
6
7
8
9
In case of failure of the panel:
DIP-SWITCH
ON
- Check voltage supply. It must be 230V 50Hz single-phase
- Check fuses
OFF
2
3
4 5 6 7 8
- Check photocells if contacts are normally closed
- Check all NC contacts
- Check that no voltage drop has occurred from the control
panel to the electric motor
F4 Fuse = 1A
TRANSFORMER
24V Transformer
Protection
10 11 12 13 14 15
23 24
29
F3 Fuse = 630mA
Transformer Protection
F2 Fuse = 8A
Mains
F1 Fuse = 8A
Mains