LOW VOLTAGE ELECTRICAL CONNECTIONS
Photocells and Safety Edge:
1 2
PHOTOCELLS
AND SAFETY EDGE
Radio Contact:
- Open/Close (Standard)
- Travel reversing on
pulsing
- Step by step
24V 3W Indication Light:
3
11
Light ON = Open gate
Light OFF = Closed gate
Flashing (fast) 0.5s= Closing gate
Flashing (normally) 1s= Opening gate
Flashing (slowly) 2s= gate is stopped
HIGH VOLTAGE ELECTRICAL CONNECTIONS
Capacitor and Single-phase Motor:
29 30
16 17
18
-
MOTOR RUN
Capacitor
M
20µF for 0.5HP
OPEN/CLOSE
40µF for 1.0HP
FROM 2 UP TO 128s

OPERATING MODES

Automatic / Semiautomatic:
Automatic Operation: any pulse opens the gate, the gate stays
open as long as the Dwell time expires as set by R64 trimmer, then
it closes automatically, no pulsing is required.
Semi-automatic Operation: any pulse opens the gate that stays
open. A second pulse to Close is required for the gate to close.
DIP-SWITCH 3
Trimmer R64
ON= Automatic Closing
-
+
OFF= No Automatic. Semi-automatic
3
Dwell Time
closing by pulse
from 2 to 128s
Time clock:
How it works: Set the clock to the required times. On the pre-set time the gate is automatically opened and held open. Any further pulsing (even
by remote control) is not accepted by the system until the time pre-set by the clock has expired. On expiring and after the pre-set dwell time
the gate is closed automatically.
R62 trimmer on to zero, Dip-Switch 3=ON.
DIP-SWITCH No.3=ON Automatic Closing
ON= Automatic Closing
-
+
OFF= No Automatic. Semi-automatic
Pedestrian Trimmer R62
3
set on to zero
4086
Drwg. No.
12 13
24V OUTPUT (MAX. LOAD:
2 PAIRS PHOTOCELLS
1 RADIO RECEIVER)
DIP-SWITCH 2 and 5 (NEVER set BOTH of them ON
3
7
at the same time):
ON: Gate is not reversed while opening
OFF: Any pulse reverses the gate
2
ON: Step by step. Stop in between
OFF: Standard operating mode
5
Flashing lamp:
R65
R64
19 20
-
+
+
DWELL TIME
TIME
FROM 2 UP TO 128s
230V MAX 25W
Pedestrian Opening:
-
from 3 to 30s. It can be activated by
any pulse (eg. by remote control)
closing by pulse
DIP-SWITCH 1:
ON: Photocells stop gate while opening,
reverse it once obstacle is removed
OFF: Photocells do not stop gate while
1
opening, reverse it in case of an
obstacle
Push Button Switch Pulin 3:
3
Safety Contact:
This contact must be
14 15
N.C. for the control
panel to be allowed to
work
DIP-SWITCH 4 and 7:
ON: Pre-flashing
OFF: No pre-flashing
4
ON: Lamp is not operating during
Dwell time. Automatic mode.
OFF: It flashes during Dwell Time.
7
Automatic Mode.
Hold on switched (Deadman) control:
Open and Close operations are achieved "by holding a
Trimmer R62
switch on" (no relay self-holding in involved) therefore a
+
phisical attendance is required to keep the gate opening
or closing until either the button or key is released.
superior to 2s
3
4
DIP-SWITCH 6
ON= Deadman Control. Dip-switch 4=OFF
OFF= Standard Operations
6
Button switch:
3
4
5
6
28
27
26
Led to indicate status of
Open - Stop - Close
switches
Power supply:
21 22
POWER SUPPLY
230V 50Hz SINGLE-PHASE
and Dip-switch 3=OFF
3
4
NO
Limit switch:
8
9
10
Courtesy Light
230V max. 100W:
Trimmer R63
23 24
-
+
COURTESY LIGHT
FROM 2 UP TO 255s
®
Made in Italy