PROGRAMMING
Menu
0.Exit
1.Measure
probe
2.Liquid
If the density of the stored medium is unknown, the reference height can be entered in menu
item "10.Trim height" To do this, determine the current fill level in mm, deduct 1.0 cm from it
and enter the resulting value - click YES to confirm the entry.
Should the current fill level be less than 75%, we urgently recommend that you adjust the
value after the next refuelling to achieve good measuring accuracy.
6 / 16
Input function
Press [Enter] to return to display mode
Select probe measuring range (see type label of the
probe) - default value is 250 mbar
Standard probe
100mbar
150mbar
160mbar
200mbar
250mbar
400mbar
500mbar
1.000mbar
2.000mbar
3.000mbar
5.000mbar
Set mbar
by
Calibration
Select the medium
Medium
Heat. oil
Water
Diesel
Biodiesel
RME, FAME
Rape oil
Palm oil
Motor oil
AdBlue
Regular
gasoline
Premium
gasoline
Density valve
by
Calibration
®
SmartBox
1 / SmartBox
max. Tank height for
heating oil
1.20 m
1.80 m
1.90 m
2.40 m
2.90 m
4.70 m
6.00 m
12.00 m
24.00 m
36.00 m
60.00 m
Is only indicated if item 10. Set h
or 11. Set V has been activated
Measuring range kg/m³ (15 °C)
Measuring range kg/m³ (15 °C)
845 kg/m³ - default setting
999 kg/m³
830 kg/m³
880 kg/m³
880 kg/m³
915 kg/m³
910 kg/m³
865 kg/m³
1090 kg/m³
743 kg/m³
750 kg/m³
Entry of a specific probe with
different measuring range
®
2 / SmartBox
Input value
water
1.00 m
1.50 m
1.60 m
2.00 m
2.50 m
________mbar
4.00 m
5.00 m
10.00 m
20.00 m
30.00 m
50.00 m
_______kg/m³
Part No. 28 100 57 e
®
3