After the end of setup, do not forget to replace the housing cover!
EXAMPLES FOR PROGRAMMING
Example 1: Basement tank for 6000 litres heating oil, litre indication, linear steel tank
Inner height 165 cm, (fill level 125 cm)
SmartBox
Step
1.Probe
2.Medium
3.Tank shape
4.Tank volume
5.Inner tank height
6.Exit
press [Enter] to see the indication
Example 2: Well, 7.50 m maximum water level from ground of the well, Display m
(fill level 4.20 m) relay switching function is desired.
SmartBox
Relais 1 - On at 99 %-10 % - Off at < 10 %
Step
1.Probe
2.Medium
3.Tank shape
4.Max. value
5.Inner tank height
6.Relay 1
7.Relay 2
8.Exit
press [+] key to go to
12.Indicated unit
13.Rounding
14.Exit
press [Enter] to see the indication
Part No. 28 100 57 e
®
1Standard probe 0 - 250 mbar
®
2 Standard probe 0 - 1000 mbar, indication in m water column
®
SmartBox
1 / SmartBox
Entries / selection
250 mbar
Heat.oil
Linear
6000L
(set with [+] / [-] keys)
165.0cm
(set with [+] / [-] keys)
Heat.oil
4.550 L
Entries / selection
1000 mbar (set with [+] / [-] keys)
H2O
(set with [+] / [-] keys)
Linear
7500 L
(set with [+] / [-] keys)
7500 mm
(set with [+] / [-] keys)
active On: 99 % Off: 10 %
(set with [+] / [-] keys)
deactive
m
automatic
H2O
4.20 m
®
2 / SmartBox
76 %
56 %
®
3
9 / 16