possible if the configuration and
operating PC are located in the same
subnet and use the same address
area, e.g. 192.168.0.xxx
Terminal assignment
E1/E1
Input 1
E2/E2
Input 2
E3/E3
Input 3
E4/E4
Input 4
E5/E5
Input 5
W0/W1/W2
Output 1
W3/W4/W5
Output 2
W6/W7/W8
Output 3
W9/W10/W11 Output 4
+M/-M
Supply
10 - 36 V DC
Da/Db
connection
Siedle Vario bus
Wiegand 1
Wiegand terminal
Card reader
Wiegand 2
Wiegand terminal
Card reader
LAN 10/100
Network connection
LED operating displays
• Power
Indicates whether mains power is
available
• Status
Indicates that the TCIP 602-... is
operational
• Error
Indication of error status
• Wiegand 1
Sabotage display for reader 1
• Wiegand 2
Sabotage display for reader 2
• LAN
Network status display
• E1 - E5
Display input 1 - input 5
• A1 - A4
Display output 1 - output 4
Installation
7 Install the TCIP 603-... in
accordance with the wiring diagram.
If several input modules are
connected to the TCIP 603-... , the
address (Addr. 1-8) number must be
set at the input modules.
8 Installation of the TCIP 603-...
with the extension FSM 740-... and
SCE 640-...
6
The TCIP 603-... is connected to a
TCP/IP network via a CAT5 cable at
the LAN socket. In its as-delivered
status, the TCIP 603-... has the IP
address 192.168.0.1 (subnet mask
255.255.255.0). The controller
is configured via a web browser,
meaning that no special software
needs to be installed. Configuration
is possible via any PC connected to
the network PC.
Dialling the TCIP 603-...
• Establish the connection via the
network to the TCIP 603-...
• Start the Internet Explorer or
compatible browser
• Enter http://192.168.0.1 in the
address line
• The configuration registration
window appears in the browser
• Enter the user name Service and
password Siedle, (case sensitive),
then click the Log in button
Commissioning
The input mask divides into 4 areas:
• Hardware/system
• Configuration
• Reports
• Tools
• Hardware/system
• Inputs
Configuration of potential inputs
E1 - E5 of the TCIP 603-... e.g. for
call buttons or door sensor.
• Outputs
Configuration of potential-free
outputs A1 - A4
• Readers
Search for all modules for access
control connected to the Vario bus.
Once the modules have been read
in, every module can be assigned an
unambiguous name.
• Network
Change of the fixed IP address,
subnet mask and standard
gateway. It is possible to modify the
configuration timeout.
• System time/time change
Setting the date and time
Configuration
• Doors
In this menu, the individual doors
are generated.
• Time profiles
Generation of time profiles
• Public holidays/Vacation
Input of public holidays or days on
which the access control system only
admits certain groups of users.
• Access groups
Up to 40 access groups can be
generated. e.g. IT access group or
cleaning personnel.
• Users
Input of individual users with names
for unambiguous identification.
One user can be assigned to several
different access groups.
Reports
• Event log
Display of the last used inputs and
outputs with indication of the user
name and relevant door. Historic
entries can be found using a filter.
• Presence list
Display of currently present persons
who have passed by a connected
module of the access control
system. This function is only possible
if output readers are configured at
the TCIP 603-... .
• Absence list
Display of currently absent persons.
This function is only possible if there
are output readers configured at the
TCIP 603-... .
Tools
• Password
Changing the password for the user
currently logged in.
• Alarms/status messages
Display of alarm and/or status
messages.
• Direct actuation of the door
release
Actuation of connected door
releases via the program user
interface.
• Memory utilization
Display of available doors, time
profiles, access groups, users and
public holidays.