6 Troubleshooting

6.1 LED Indicator

See "Tab. 4-2 Indicator Status Description" for the definition.
Fault Type
LED
indicator
cannot be lit.
Green
indicator
goes out.

6.2 Errors on the App or LCD Screen

If an error occurs, the "Error" state will be shown on the main screen of the
inverter.
We need the following information to provide you with the best assistance:
 inverter type (e.g. string, central, grid-connected, hybrid, transformerless,
single phase, triple phase, single MPPT, multiple MPPTs);
 product name;
 serial number of the inverter;
 error code / name; and
 a brief description of the problem.
Code
Description
Grid over-voltage.
The
002
exceeds the protective
value.
20
Troubleshooting
1. Disconnect the AC circuit breaker.
2. Rotate the DC switch to "OFF".
3. Check the polarity of DC input.
1. Disconnect the AC circuit breaker.
2. Rotate the DC switch to "OFF".
3. Check the inverter electrical connection. Refer to "3
Electrical Connection".
4. Check whether the voltage of DC input exceeds the
inverter start-up voltage.
5. If all the above conditions are OK, please contact
SUNGROW.
grid
voltage
Troubleshooting
1. Check the voltage of the grid.
2.
If
the
grid
permissible range of inverter protection
parameters, ask utility grid company for
solution.
3. If the grid voltage is within the permissible
range, contact Sungrow Service Dept.
voltage
exceeds
the