Switching On
Insert the plug into the mains wall socket and
switch it on..
The power on light should illuminate, the ap-
pliance will produce steam and the tank will
become pressurised. Heating time is approxima-
tely 5 minutes with cold water. Filling boiler with
hot water will shorten heat up time.
The heater is repeatedly switched on during
operation, in order to maintain constant steam
pressure.
NOTE: Do not switch the steam cleaner on if
there is no water in the boiler.
CAUTION: Read the instructions for "Filling your
Steam Cleaner With Water" (below) before
opening the Safety Filler Cap.
CAUTION: Always unplug before filling.
IMPORTANT: Do not add cleaning solutions,
scented perfumes, oils or any other chemicals
to the water used in this appliance. Use only tap
water or if the tap water in your area is very hard
use distilled/purified water.
Filling Your Steam Cleaner With Water
Step 1: Before filling the steam cleaner, remove
the plug from the mains wall socket.
Step 2: Turn Safety/Filler Cap counter clockwise
until removed.
Step 3: Using the filler funnel add 1.2L (2 pints) of
water. Do not overfill. Replace Safety/Filler Cap
by turning clockwise.
Step 4: Plug the unit into a standard 220volt
wall socket .
Step 5: Allow approximately 5 minutes for
steam to reach its working temperature and
pressure..
Step 6: Connect desired attachments onto the
Flexible Steam Hose.
CAUTION: Always drain condensate from hose
before use or if unit has been left idle for a
period of time. To drain hose, direct nozzle into
an appropriate container or sink and switch on
the steam. When hose has been drained, nor-
mal use may be resumed. Never direct nozzle
towards people, animals or plants.
Operating Instruction
Regulating the volume of steam
The amount of steam can be regulated accor-
ding to requirement by sliding the steam control
on top of the steam gun. Forwards to increase
steam, backwards to reduce steam.
IMPORTANT: When the Monster 60 SuperClean
has run out of water, steam output will cease.
CAUTION: Allow unit to cool for 5 minutes before
refilling. If refilling the machine while still hot, the
first drops of water may bubble up.
Extreme care should be taken when opening
the Safety/Filler Cap as cap may become hot
during use and escaping steam can cause
scalding.
Refilling the boiler
Step 1: remove the 3-pin plug from the wall
socket.
Step 2: Cover the safety filler cap with a towel or
cloth and carefully loosen it by turning counter
clockwise. If the tank has not been completely
vented any residual steam will be released be-
low the safety/filler cap. When the hissing stops
and the last of the steam has been released,
remove the filler cap.
Step 3: Allow the steam cleaner to cool for 5
minutes before re-filling with water. If the steam
cleaner is still hot, there is a risk that water
will be squirted back during filling and cause
scalding.
Step 4: Refill water tank with a maximum of 1.2L
(2 pints) of water using the filler funnel.
Only use the filler funnel supplied. Its nozzle is
made from a heat resistant material to prevent
it from melting when filling a hot boiler. Other
plastic items can melt and become welded
to the inside of the boiler spout voiding your
warranty.
Step 5: Firmly screw the safety filler cap back
onto the unit by turning clockwise.
Step 6: Connect the 3-pin plug to the wall
socket.
Switching the cleaner OFF
Remove the 3-pin plug from the wall socket.
Any remaining water can be left in the clea-
ner.
22