Safety Instructions .......................................................................1
Installation Instructions ............................................................ 2-3
Electrical Wiring Diagram ...........................................................3
Operation .................................................................................. 3-4
Maintenance Section ....................................................................4
Troubleshooting ...........................................................................5
Vea el Español en el interior.
Read And Save These Instructions
Safety Rules
1. Read instructions carefully.
2. Electrical hook up should be done by a qualifi ed electrician, so
that all electrical wiring will conform to your local standards.
3. Always DISCONNECT POWER and UNPLUG motor and
pump inside the cooler before installing or performing any
maintenance.
4. Motor and pump have a grounded, molded plug and an automatic
thermal overload switch which will shut motor off when it
overheats. The motor will restart automatically when it cools
down.
WARNING:
To reduce the risk of fi re or electric shock, do not
use this fan with any "solid-state fan speed control device."
110498-3
AD2C51
AS2C51
AU2C51
AD2C5112
AS2C5112
AU2C5112
AD2C71
AS2C71
AU2C71
AD2C7112
AS2C7112
AU2C7112
Table Of Contents
www.championcooler.com
Circle the model of your cooler and
record the serial number below.
Encierrre con un circulo el modelo de su
enfriador y escribe el número de série abajo.
Serial #
Número De Série
Warranty .......................................................................................5
Parts List (Down Discharge Units) .......................................... 6-7
Parts List (Side Discharge Units) ............................................. 8-9
Parts List (Up Discharge Units) ........................................... 10-11
Specifi cation Tables (Tablas de Especifi caciones) .....................12
Instrucciones en Español ..................................................... 12-16
Evaporative Cooling
Evaporative cooling is nature's way of cooling. When air is moved
over a wet surface, water is evaporated and heat is absorbed. When
stepping out of swimming pool with the wind blowing, evaporative
cooling makes you feel cool, even though the air may be warm.
This unit works on the same principle. Air is drawn across wet
fi lter pads where the air is cooled by evaporation and then circulated
throughout the building. It is this combination of cooled air and the
movement of air over the skin which makes it feel cool.
Unlike refrigeration systems which recirculate the air, an evaporative
cooler continually brings in fresh air while exhausting old air. You
are completely replacing the air every 2 to 4 minutes by opening
windows or doors or a combination of both. The air is always fresh,
not stale, laden with smoke and odors as happens with refrigerated
air conditioning.
11-14

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Champion cooler Master Cool AD1C51

  • Página 1 Models AD1C51 AD2C51 AS1C51 AS2C51 AU1C51 AU2C51 AD1C5112 AD2C5112 AS1C5112 AS2C5112 AU1C5112 AU2C5112 AD1C71 AD2C71 AS1C71 AS2C71 AU1C71 AU2C71 AD1C7112 AD2C7112 AS1C7112 AS2C7112 Circle the model of your cooler and AU1C7112 AU2C7112 record the serial number below. Encierrre con un circulo el modelo de su Read Carefully All Of This Manual enfriador y escribe el número de série abajo.
  • Página 2 Cooler Installation The control box is factory wired and installed for either 120V or 230V operation depending on the model you purchased. The supply power should be adequately protected against overloads and short circuits. CAUTION: Make sure that the mounting surface is strong Note: Electrical installation should be performed by a qualifi...
  • Página 3: Wiring Diagrams

    • Check amperage. With pads wet and unit started, check amperage Manual Operation draw with an amperage meter. The fan speed and pump are set by the user. • Adjust pulley if necessary. If amperage draw is less than motor To activate the manual mode from the ‘Off’...
  • Página 4 Required Exhaust Openings IMPORTANT: In order to get the best performance from your cooling pads, they must be installed properly. If you have pur- chased a pad with two equal angles, the following instructions can An often misunderstood concept of evaporative cooling is the amount be disregarded.
  • Página 5: Troubleshooting Guide

    Lifetime Limited Coverage on water reservoir against any leakage due to defects in material. From date of purchase, if any original component part provided by Champion Cooler fails due to defect in material or factory workmanship only, we will provide the replacement part as follows: One year on the cabinet components.
  • Página 6: Replacement Parts List / Lista De Piezas De Repuesto

    Replacement Parts List / Lista De Piezas De Repuesto When ordering parts, please be sure to furnish the following information on all orders. Failure to do so may delay your order. / Al pedir piezas, incluya toda la información siquiente con su pedido. El no proporcionar toda esta información resultará en una demora. Cooler model number / El modelo de su enfriador Cooler serial number / Número de serie de la unidad Description and part number / Descripción y número de pieza...
  • Página 7: Replacement Parts / Piezas De Repuesto

    Replacement Parts / Piezas De Repuesto AD1C51, AD2C51, AD1C5112, AD2C5112, AD1C71, AD2C71, AD1C7112, AD2C7112 110498-3...
  • Página 8 Replacement Parts List / Lista De Piezas De Repuesto When ordering parts, please be sure to furnish the following information on all orders. Failure to do so may delay your order. / Al pedir piezas, incluya toda la información siquiente con su pedido. El no proporcionar toda esta información resultará en una demora. Cooler model number / El modelo de su enfriador Cooler serial number / Número de serie de la unidad Description and part number / Descripción y número de pieza...
  • Página 9 Replacement Parts / Piezas De Repuesto AS1C51, AS2C51, AS1C5112, AS2C5112 AS1C71, AS2C71, AS1C7112, AS2C7112 110498-3...
  • Página 10 Replacement Parts List / Lista De Piezas De Repuesto When ordering parts, please be sure to furnish the following information on all orders. Failure to do so may delay your order. / Al pedir piezas, incluya toda la información siquiente con su pedido. El no proporcionar toda esta información resultará en una demora. Cooler model number / El modelo de su enfriador Cooler serial number / Número de serie de la unidad Description and part number / Descripción y número de pieza...
  • Página 11 Replacement Parts / Piezas De Repuesto AU1C51, AU2C51, AU1C5112, AU2C5112 AU1C71, AU2C71, AU1C7112, AU2C7112 110498-3...
  • Página 12: General Specifi Cations / Especifi Caciones Generales

    General Specifi cations / Especifi caciones Generales Weight (lbs.) Cabinet Dimensions (in.) Duct Opening (in.) Peso (libras) Dimensiones De La Caja (pulgadas) Abertura De Ducto (pulgadas) Models Modelos Operating Height Width Depth Width Height Seco Lleno Altura Anchura Profundidad Anchura Altura AD1C51, AD2C51, AS1C51, 17 3/4...
  • Página 13: Instalación Del Enfriador

    Instalación Del Enfriador La caja de control es instalado y atado con alambre en la fábrica para el alimentación de 120V o de 230V, dependiendo del modelo comprado. La alimentación eléctrica se debe proteger adecuadamente contra sobrecargas y PRECAUCIÓN: La superfi cie en que ha de colocarse el en- circuitos cortos.
  • Página 14: Funcionamiento Del Termostato

    • Revise el amperio. Con los fi ltros mojados y la unidad en funciona- Funcionamiento Manual miento, revise el amperio del motor con un medidor de amperio. La velocidad del ventilador y la funcionamiento de la bomba son determi- nados por el usuario. •...
  • Página 15: Mantenimiento

    ¿Cuanto Debe Abrir Las Ventanas? IMPORTANTE: Para que el enfriador funcione lo mejor, debe instalar el medio evaporativo correctamente. Si usted ha comprado fi ltros con dos ángulos iguales, las instrucciones siguientes no serán provechosas Un concepto a menudo entendido mal de enfriamiento por evaporación es la para usted.
  • Página 16: La Localización De Averías

    Garantía limitada de por vida en la base original del enfriador en caso de gotera de agua debido a un defecto del material. A partir de la fecha de compra reemplazaremos estos componentes originales proporcionados por Champion Cooler que fallen solamente debido a cualquier defecto de materiales o mano de obra en la fábrica. Reem- plazaremos las piezas en lo siguiente: Un año por los componentes del caja.

Tabla de contenido