In the outside area near the intercom, the connection cable (4)
should not be laid on the surface of the rendering, but taken
through the wall. This protects it from damage.
Montage der Türstelle
The door intercom is qualified for concealed or surfaced
mounting. We recommend surfaced mounting.
Surface mounting:
Induct the connection wire 10-15 cm thru the slot at the surface
mounting plate. Fix the surface mounting plate at the requested
position at the wall.
Abb. 1
2x
X
Abb. 2
Abb. 3
15
X =Wire to the inside intercom
Y= wire for door opener, only
needed if door opener will be
connected.
2. Put a screw driver into the notch
Y
and lever the cover up. Now you
can pull them up or down from the
cage( see pic.2)
3. Connect wire according picture B
4. Fixing the door place by 2
threaded screws (Pic 3)
5. Pull on the covers again