Installation preparation

9
CAUTION
Ensure that there are no electric wires, gas or
water pipes in the area where holes are to be
made.

Check wall

The walls must be smooth, vertical, and sufficiently
load-bearing.
The depth of the bore holes must be the same
length as the screws. The wall plugs must have a
secure grip.
Suitable fasteners must be used for other
structures, such as plasterboard, porous concrete,
and poroton bricks.
The max. weight of the appliance is
Only specialist personnel may create the required
wall breakthrough. The building support structure
must remain in place.
Risk of damage caused by returning condensate.
Install the wall breakthrough with a slight outward
gradient (1° downward slope).
6

Electrical connection

9
The required connection information is on the
appliance's identification plate.
This appliance meets EC radio interference
suppression requirements.
This appliance may only be connected to a correctly
installed grounded socket.
Fit the grounded socket in close proximity to the
appliance.
.
7 kg
WARNING
Risk of electric shock
Parts inside the appliance can have sharp edges.
The connection cable can be damaged. Do not
bend or pinch connection cables during
installation.
The grounded socket should be connected via its
own circuit.
If the grounded socket is no longer accessible after
installing the appliance, an all-pole isolating switch
(e.g. circuit breaker, fuses and contactors) with at
least a 3 mm contact gap must be included in the
installation.