3.1 CONNECTING TO THE BOARD WITH
BUS 2EASY
CONFIGURING THE DIP-SWITCHES
Position the dip-switches ( 1 or 2) in order
to specify:
- 1CH or 2CH mode of operation (Dip-switch 5)
- the commands that the XTR B transmits to the
board (Dip-switches 1-2-3-4)
!
For each control device connected to the
BUS 2easy line, position the dip-switches so
that a command is used only on one device.
In order to add an XTR B to an existing sys-
tem you must know which commands are
already used on the other BUS 2easy devices
that are present. See the instructions for
the devices that are already installed in
1 1CH mode
ON
Dip 5 = OFF
1 2 3 4 5
Dip-switch
command
1 2 3 4
0 0 0 0
Open A_1
0 0 0 1
Open A_2
0 0 1 0
Open A_3
0 0 1 1
Open A_4
0 1 0 0
Open A_5
0 1 0 1
Stop
0 1 1 0
Stop NC*_1
0 1 1 1
Stop NC*_2
1 0 0 0
Close
1 0 0 1
Open B_1
1 0 1 0
Open B_2
1 0 1 1
Open B_3
1 1 0 0
Open B_4
1 1 0 1
Open B_5
1 1 1 0
not used
1 1 1 1
not used
* Stop NC, also generates a Stop when the XTR B is disconnected.
XTR B
order to identify which commands are already
used. For future reference, you can make a
note of the IDs of the installed devices in
the table at the end of this manual. Any
BUS 2easy photocells or BUS 2easy safety
edges do not interfere with the control de-
vices. Their dip-switches can be ignored.
2 2CH mode
ON
1 2 3 4 5
Dip-switch
1 2 3 4
0 0 0 0
0 0 0 1
0 0 1 0
0 0 1 1
0 1 0 0
0 1 0 1
0 1 1 0
0 1 1 1
1 0 0 0
1 0 0 1
1 0 1 0
1 0 1 1
1 1 0 0
1 1 0 1
1 1 1 0
1 1 1 1
1 = ON ; 0 = OFF
5
Dip 5 = ON
Command 1
Command 2
Open A_1
Open B_1
Open A_1
Open B_2
Open A_1
Stop
Open A_1
Close
Open A_2
Open B_1
Open A_2
Open B_2
Open A_2
Stop
Open A_2
Close
Open A_3
Open B_3
Open A_3
Open B_4
Open A_3
StopNC*_1
Open A_3
Close
Open A_4
Open B_3
Open A_4
Open B_4
Open A_4
StopNC*_2
Open A_4
Close
532109 - Rev.A