FIRST STORAGE OF A TAG-GROUP
The XTR B must be in standby. The memory of the
Group selected must be empty.
1. Select the group: press the button the same
number of times as the number of the Group
(eg.: Group 3, press 3 times).
- After 2 s, the XTR B will BEEP and flash the same
number of times as the number of the Group.
- It will flash for 20 s (storing enabled).
2. Bring the Tag close to the reader.
- The XTR B will BEEP the same number of times as
the number of the Group and the LEDs will come
on for 2 s: the Tag is enabled.
- Flashing will resume for 10 s (storing enabled).
3. Repeat step 2 for any additional Master Tags that
are required for the Group.
- The XTR B will BEEP once and the LEDs will
come on for 2 s after each additional Tag has
been enabled.
4. To finish, let 10 s pass without bringing any
new Tags up to the reader (or press the button
immediately).
- The LEDs turn off: XTR B in standby.
Repeat the procedure to enable one or more tags of
another Group. At step 1, assign an available Group.
Errors during storage process
During step 1, the XTR B signals
an error, then the LEDs turn off:
Group not available
During step 1, after a BEEP or se-
ries of BEEPS equal to the group
number, XTR B memorisation is
not active (LEDs on, NO flashing
for 20 secs): the group is already
stored in the memory
During step 3, the XTR B signals
an error, then the LEDs turn off:
the Tag has not been stored in
the memory
ERROR warning: Five BEEPS and 5 flashes
in quick succession.
XTR B
Solution
Repeat the process
correctly
Carry out the "Add
Tag" process for
the group
Carry out the "Add
Tag" process for
the group
8
FIRST STORAGE OF A Tag-GROUP
N times (N = Group number)
1
SW2
2 s N ( ) ,
... 20 s MAX
2
First Master Tag of the Group
N + 2 s: Tag OK ,
... 10 s MAX
3
Additional Master Tag of
the Group
1+ 2 s: Tag OK ,
timeout without Tag:
4
SW2
20 s ( timeout)
10 s ( timeout)
10 s timeout
END
532109 - Rev.A