5. OPERATION:___________________________________________________________________________________________________
5.1. System stopped
The system enters "stand-by" MODE when the "
production in the electrolysis cell.
5.2. Selection of the level of production
To select the required production level, press the "
keeps flashing. After a few seconds have elapsed, the system will set production to the level selected.
WINTER Mode: during periods of low water temperature, where the chlorine demand will be low, select a production level [1] of 50%,
because in this way power consumption and lifetime of the package of electrodes are optimized.
5.3. TEST Mode
To enter TEST MODE, reduce the production level to "0%" by pressing the "
Once the system has stopped, hold down this key for 5 seconds. The system will indicate that it has entered TEST MODE and all the leds will
light up for one second.
When the system enters TEST MODE, the system resets the polarity change timer and the level of production selected. In this mode, the
system is totally operational, and the electrode polarity reversal will be performed every 2 minutes. To quit TEST MODE, the system must be
switched off from the 230 V mains.
When the system is in TEST MODE, the polarity led "DIRECT – REVERSE" [2] will flash.
-
" key [3] is pressed successively until the "0 %" led flashes. In this situation there is no
Fig. 13
+
-
" [4] or "
" key [3] successively until the led corresponding to the target production level
Fig. 14
-
" key in a row [3] (Fig. 13).
Fig. 15
10