NOTICE
Important notice about iron, manganese and copper in the
water supply
Iron and Manganese
Just as with conventional water softening media, OneFlow
to be protected from excess levels of certain metals that can easily
coat the active surface, reducing its effectiveness over time. Public
water supplies rarely, if ever, present a problem, but if the water
supply is from a private well, confirm that the levels of iron (Fe) and
manganese (Mn) are less than 0.3 mg/L and 0.05 mg/L respec-
tively.
Copper
Pursuant to the EPA drinking water standards, the copper con-
centration permitted is up to 1.3 ppm. Typically originating from
new copper plumbing, high levels of copper can foul OneFlow
media. For applications with copper concentration greater than
1.3 ppm, please consult Watts Water Quality Technical Service.
To further minimize any problem with excess copper, avoid ap-
plying excessive flux on the inner surfaces of the pipe and use
a low-corrosivity water soluble flux listed under the ASTM B813
standard.
CAUTION
!
• Not for use on closed loop systems.
• Do not let the system freeze. Damage to the tank may
result.
• System must be operated in a vertical position. Do not lay
it down during operation. The system may be placed in any
position for shipping and installation but must be operated
in the vertical position.
• Place the system on a smooth, level surface. Because the
system operates in an upflow, fluidized bed mode, having a
level surface is more important than with a softener or media
filter.
• A bypass valve should be installed on every system to facili-
tate installation and service.
• Observe all local plumbing and building codes when install-
ing the system.
RE: Installation
NOTICE
The OneFlow
system differs from a conventional softener or
®
media filter in a number of key respects.
• The system is light and only partially filled with media. This is
normal. The upflow operation of the system requires a lot of
freeboard to allow the bed to fully fluidize.
• The system has no underbed so you can tip the system
over without any fear of upsetting the media. This makes
transportation and installation much easier than conventional
systems.
• Because the OneFlow
system operates in the Upflow mode,
®
the tank connections are opposite of what you're used to.
• Please see the Important note about iron, manganese and
copper above.
• Please see the note about "Using OneFlow
water treatment equipment" on the next page.
!

Installation Precautions

• Do NOT install system on line pressure above 100psi.
• Do NOT install the system backwards with the feed water
line connected to the outlet.
needs
®
• Do NOT install system in direct sunlight or where system is
exposed to harsh chemicals or may be subjected to being
struck by moving equipment, carts, mops or any other item
that may cause damage.
• Do NOT install the unit behind equipment where it may be
difficult to access the system for filter replacement.
• Do NOT install the OneFlow
heat. Also, do not install the system near any device or
break out area that would be adversely effected by water.
• IF water hammer is evident, install water hammer arrestors
before the OneFlow
• Always back-up valves and fittings with a wrench when
installing a fitting to avoid turning the valve.
Position the OneFlow
!
Using OneFlow
equipment.
Due to the unique properties of OneFlow
unique requirements for using OneFlow
filtration or other forms of water treatment.
1. OneFlow
not install any filters after OneFlow
for which scale prevention is required. POU filters, e.g. car-
bon or RO are exempt from this requirement.
2. The addition of soaps, chemicals, or cleaners, before or
after OneFlow treatment, may reverse its anti-scale treat-
ment effects and/or create water with a heavy residue
or spotting potential. Any adverse conditions caused by
the addition of soaps, chemicals, or cleaners are the sole
responsibility of the end user.
with other
®
4
WARNING
®
unit.
®
unit in a suitable location.
®
WARNING
with other water treatment
®
must be the last stage in the treatment chain. Do
®
system near any source of
, there are some
®
in conjunction with
®
or before any devices
®