SmartFLeX SSEL8403 Manual De Uso página 16

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

To reduce the pressure proceed as follows:
1. Slowly open the dump valve on the Pressure Test Unit.
2. When the following screen is displayed quickly close the dump valve.
Nominal Test
Pressure
Graphic shows
pressure is OK
The Multi-Function Welding Unit is now ready to commence the pressure test.
Press the ENTER
key to start the recorder. Each pressure reading is
noted by a tone and the following screen is displayed:
Nominal Test
Pressure
Initial Ambient
Temperature
If, during the test, the pressure drops below the Minimum allowed Pressure
(MP) then the error message shown on the right is displayed.
The pressure test can be stopped at any time by pressing the ESCAPE
key. Then the screen on the right will appear.
If the pressure test is completed successfully, the screen shown on the right is
displayed.
In all the above cases pressing the ESCAPE
Function Welding Unit to show the following screen:
Press the ENTER
key to go back to read the pressure test barcode, press
the ESCAPE
key to go back to the general data input ("site" screen, see
page 8).
Pressure OK
NP = 4.0 AP= 4.01 Bar
= = =
PRESS [ENT]
Current Pressure
Reading 1 of 240
NP= 4.01 AP=4.10 Bar
IT=25.0
AT=25.0 °C
Test Running ....... /
Graphic shows data
acquisition is running
key will cause the Multi-
Repeat = ENT
Other = ESC
14
Actual Test
Pressure
Current
Temperature
ERROR n. 201
Low Pressure
MP=3.9 AP=3.89
PRESS [ESC]
ERROR n. 200
User stops manually
PRESS [ESC]
Test Completed
Successfully
PRESS [ESC]

Publicidad

Tabla de contenido
loading

Productos relacionados para SmartFLeX SSEL8403