Magnet:
Installa on with screws: remove the back panel from the magnet by
sliding it off. Then, posi on the back panel at the desired posi on. Now,
a er the magnet back panel has been mounted, put the magnet on the
back panel and slide it downwards un l it is in its final posi on.
Installa on with double-sided tape: peel off the protec ve foil from one
side and s ck the tape onto the magnet. Then, peel off the other part of
the protec ve foil and s ck the magnet onto the door or doorpost.
Sensor:
Before installing the sensor, please assure that both the magnet and sensor
will be aligned as described in the chapter "How to mount a door sensor".
Sideways installa on and installa on with double-sided tape: Peel off the
protec ve foil from one side of the tape and s ck the tape onto the
sensor. Then, peel off the other part of the protec ve foil and s ck the
sensor onto the door or doorpost. Secure the sensor with the included
screw at the bo om of the sensor.
Installa on with screws: Slide the sensor upwards and remove it from the
back panel. Then,posi on the back panel at the desired posi on. Now,
place the sensor on the back panel and slide it downwards. Secure the
sensor with the screw at the bo om of the sensor.
Test your door sensor
1. A er the installa on, open the window or door.
2. The red indicator light on the front of the sensor will flash once.
3. The sensor is now correctly setup.
11.PIR mo on sensors
Product Overview and ac va on
Detector window
Indicator light
Open the back panel to insert the ba eries. Please note the correct polarity.
Now, close the back panel again. Slide the ball joint in place un l it locks. Do
not yet posi on the wall mount. Please first carefully read the sec ons
"General installa on guidelines" and "How to mount a PIR mo on sensor"
before you install the mo on detector.
General installa on guidelines
Avoid posi ons close to a window, air condi oners, fluorescent lights,
heaters, refrigerators, stoves, and direct sunlight and other places where
thetemperature would change rapidly, and where airflow is high. If there are
two detectors in the same detec ng range, please adjust the posi on to
avoid interference and false alarms.
IMPORTANT: The Infrared detector is sensi ve to a human's horizontal
movement. The detector is less suscep ble to ver cal movements.
Therefore, it is advised to aim the device at a 90 degrees' angle to a
person's walking direc on.
How to mount a PIR mo on sensor
Unlike magne c door and window sensors, PIR mo on sensors recognize
heat differences. Some mes heat differences are unno ceable. Our PIR
mo on sensors feature advanced algorithms that help to detect the
difference between a human being and environmental heat changes.
However, it is essen al to carefully select the right posi on of PIR mo on
sensors for it to func on correctly.