Parts Description - Port-A-Cool KUULAIRE KA55 Manual De Operación

Ocultar thumbs Ver también para KUULAIRE KA55:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

LOCATION
6 6
ELECTRICAL

PARTS DESCRIPTION

ASSEMBLY INSTRUCTIONS
Model No.
Voltage
ELECTRICAL
Frequency
Current
TROUBLESHOOTING
Water Tank Capacity 8 gallons
Dimensions
Shipping Weight
ASSEMBLY INSTRUCTIONS
Motor
WARRANTY
TROUBLESHOOTING
CLEANING AND MAINTENANCE
Symptom
WARRANTY
No discharge of air
NOTES
Not cooling
CLEANING AND MAINTENANCE
REMOTE CONTROL
Odor emission
NOTES
Water droplets coming
USE AND OPERATION
out of air outlet
REMOTE CONTROL
The unit will not respond
!
USE AND OPERATION
Unit is making noise
!
manufactured by port-a-cool, llc
KA55
120VAC
60Hz
2.4 A
H 34" x W 18" x D 14"
30 lbs.
Class A, Themally Protected
Possible Cause
Cord is not plugged in
Power is not on
Circuit breaker/gFCI
Water tank is not locked properly
Pump is not turned on
Low/No water
Damaged pump
Brand new unit
Old unit with algae
Calcium saturated water
Clogged cooling pad
Damaged PCB
Moisture in PCB
Remote control batteries
Calcium build up in blower
®
Possible Solution
Make sure cord is plugged in and try to turn the unit on pressing buttons
on control panel and remote control. Check the circuit breaker or check
gFCI reset button.
Make sure the water tank is assembled and locked properly.
Check the water level and turn on the pump by pressing COOL button.
Make sure COOL button/Low Water icon are not flashing (low/no water) -
refill the tank
Replace pump
Brand new cooling pad will initially have an odor which will dissipate within a
week of initial use. If the unit is not new, there may be an algae issue
– replace the pad and maintain regularly.
Drain water, deep clean and clean the cooling pad.
Cooling pad may need to be replaced.
Try with remote control. If the unit responds, PCB board fasteners loose.
If neither control panel nor remote control command works, PCB board
damaged – replace PCB.
Try using remote control to see if the unit responds. If the unit responds
briefly, likely cause is the moisture in the PCB. Turn off unit by unplugging
it from the power. Drain, clean and dry the unit, possibly replace the cooling
pad. Refill it with fresh water.
Check batteries.
Deep clean the unit -remove calcium debris.
Port-A-Cool, LLC