Installation and Use
1. All PFAS components must be selected and deemed compatible with applicable SRL by a
Competent Person.
2. Ensure structure to which SRL is to be attached, and on which work is to be performed, is free
of all hazards, including, but not limited to, debris, rot, rust, sharp or abrasive edges and
surfaces, and hazardous materials.
3. Eliminate or minimize all risk of swing fall hazard.
4. Edge Angel SRLs may be used in stationary applications ONLY. Attach Edge Angel SRL carabiner
to selected anchorage connector, and attach snap hook to applicable harness D-ring.
5. Ensure 100% tie-off will be maintained at all times, which may require the use of a back-up
or supplementary fall protection system.
LE SRL Additional Use Instructions:
!
ALWAYS adhere to the following warnings and specifications when using LE SRLs.
WARNING
Edge Angel SRLs, EXCEPT for part # 10908, are tested and certified for horizontal use over a steel
edge without burrs. Edge Angel SRLs may be used over similar surfaces, such as metal sheeting
or other steel formations.
The allowable angle of redirection of the lifeline portion of Edge Angel SRLs at the leading edge
of a fall hazard MUST be at least 90° (see Image 1).
Anchor point MUST be situated no lower than the leading edge of applicable fall hazard(s).
Prior to use, a Competent Person MUST calculate adequate fall clearance (see pg. 6).
ALWAYS attach to anchorage connector that will allow for required setback distance
(see Image 2).
Setback distance: As determined by product testing, Guardian Fall Protection Edge Angel
SRLs MUST be installed a MINIMUM 6' (1.8m) from the leading edge of applicable fall
hazard(s).
11