Etiquetas
understand all manufacturer's instructions provided
ATTEMPT TO SELF SERVICE OR REPAIR! DO
USE:
instruction manual and labels included with this device at the
time of shipment. This device is only for use by one person as a
fall arrester. Always connect the snap hook directly to the
attachment point on the safety harness. Guard against swing-falls
by keeping the lifeline vertically overhead. Maximum free
fall 2 feet. Avoid lifeline contact with sharp or abrasive
edges and surfaces. Ensure that connection to
anchorage is secured properly before use. May be
used as a component of a PFAS in HLL applications.
Design, installation, and utilization of HLLs must be
supervised by a Qualified Person. Suitable for
horizontal use. Competent Person must calculate
adequate fall clearance prior to use; refer to
instructions for details. Minimum installation setback
Serial #
20' 3/16" CABLE
25' 3/16" CABLE
10920
10922
WARNING:
Prior to use, fully read and
DO NOT
with equipment at time of shipment.
NOT REMOVE THIS LABEL.
Always use in accordance with manufacturer's
distance from leading edge is 6 feet.
SPECIFICATIONS:
Capacity Range: 130 – 310 lbs. or 311 – 420 lbs.*
Average arresting force: 900 lbs.
Maximum arresting force: 1,800 lbs.
Maximum arresting distance: 54 in.
Class B SRL
* See instructions for additional requirements
Mfg. Date
30' 3/16" CABLE
CUSTOM
10925
INSPECTION:
Inspect unit in accordance to the
manufacturer's instruction manual and regulatory
guidelines. Check lifeline retraction by pulling out a
minimum 4 feet of lifeline and allowing it to retract under
light tension, lifeline should retract completely. Pull sharply
to test locking function, brakes must engage. Before use,
inspect the lifeline condition, function and condition of
fasteners, and legibility of labels. Also, check for evidence of
defects, damage or missing parts. User must inspect the impact
indicator for signs of activation. Device must be taken out of
service after arresting a fall or if the impact indicator show signs
of activation. Do not use if inspection reveals an unsafe
condition. Unit must be inspected by a trained and
Competent Person at least every 6 months.
STANDARDS:
ANSI Z359.14-2012, A10.32-2012
OSHA 1926.502, 1910.66
90249 (Rev. B)
J F M
A
M J
J
A
S O N D
YR
YR
YR
YR
YR
_____/_____
Date of first use
27