Installation; Electrical Equipment; Support Installation - HYTROL Gapper-D Manual De Instalación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION

• Electrical Equipment

WARNING! Electrical controls shall be installed and wired by a qualified
electrician. Wiring information for the motor and controls are furnished by
the equipment manufacturer.
CONTROLS
Electrical Code: All motor controls and wiring shall conform to the National
Electrical Code (Article 670 or other applicable articles) as published by
the National Fire Protection Association and as approved by the American
Standards Institute, Inc.
CONTROL STATIONS
A) Control stations should be so arranged and located that the operation of
the equipment is visible from them, and shall be clearly marked or labeled to
indicate the function controlled.
B) A conveyor which would cause injury when started shall not be started
until employees in the area are alerted by a signal or by a designated person
that the conveyor is about to start.
When a conveyor would cause injury when started and is automatically
controlled or must be controlled from a remote location, an audible device
shall be provided which can be clearly heard at all points along the conveyor
where personnel may be present. The warning device shall be actuated by
the controller device starting the conveyor and shall continue for a required
period of time before the conveyor starts. A flashing light or similar visual
warning may be used in conjunction with or in place of the audible device if
more effective in particular circumstances.
Where system function would be seriously hindered or adversely
affected by the required time delay or where the intent of the warning may
be misinterpreted (i.e., a work area with many different conveyors and allied
devices), clear, concise, and legible warning shall be provided. The warning
shall indicate that conveyors and allied equipment may be started at any time,
that danger exists, and that personnel must keep clear. The warnings shall be
provided along the conveyor at areas not guarded by position or location.
C) Remotely and automatically controlled conveyors, and conveyors where
operator stations are not manned or are beyond voice and visual contact from
drive areas, loading areas, transfer points, and other potentially hazardous
locations on the conveyor path not guarded by location, position, or guards,
shall be furnished with emergency stop buttons, pull cords, limit switches, or
similar emergency stop devices.
FIGURE 4A
72 (21,9 m)
Optional MS Type Floor Supports
(Soportes de piso de tipo MS opcionales)
48 (14,6 m)
All such emergency stop devices shall be easily identifiable in the
immediate vicinity of such locations unless guarded by location, position, or
guards. Where the design, function, and operation of such conveyor clearly is
not hazardous to personnel, an emergency stop device is not required.
The emergency stop device shall act directly on the control of the
conveyor concerned and shall not depend on the stopping of any other
equipment. The emergency stop devices shall be installed so that they cannot
be overridden from other locations.
D) Inactive and unused actuators, controllers, and wiring should be removed
from control stations and panel boards, together with obsolete diagrams,
indicators, control labels, and other material which serve to confuse the
operator.
SAFETY DEVICES
A) All safety devices, including wiring of electrical safety devices, shall be
arranged to operate in a "Fail-Safe" manner, that is, if power failure or failure
of the device itself would occur, a hazardous condition must not result.
B) Emergency Stops and Restarts. Conveyor controls shall be so arranged
that, in case of emergency stop, manual reset or start at the location where
the emergency stop was initiated, shall be required of the conveyor(s) and
associated equipment to resume operation.
C) Before restarting a conveyor which has been stopped because of an
emergency, an inspection of the conveyor shall be made and the cause of
the stoppage determined. The starting device shall be locked out before
any attempt is made to remove the cause of stoppage, unless operation is
necessary to determine the cause or to safely remove the stoppage.
Refer to ANSI Z244.1-1982, American National Standard for Personnel
Protection – Lockout/Tagout of Energy Sources – Minimum Safety
Requirements and OSHA Standard Number 29 CFR 1910.147 "The Control
of Hazardous Energy (Lockout/Tagout)."

• Support Installation

1. Determine primary direction of product flow. Figure 4A indicates the
preferred flow as related to the drive.
2. Attach supports to both ends of section. Hand tighten bolts only at this time.
3. Adjust elevation to required height.
12'-0" (3,7 m)
Spring Take-Up (Compensación de resorte)
12'-0" (3,7 m)
48 (14,6 m)
4
72 (21,9 m)
48 (14,6 m)