• Do not use attachment tools
which require liquid coolant.
Using water or another liquid coolant
could lead to electrical shock.
Additional safety
instructions
• Connect the appliance only to a power
socket with a residual current circuit
breaker of rated residual current no
more than 30 mA.
• Keep power cords and extension cords
away from the disc. If they are dama-
ged or cut through, immediately pull
the plug from the outlet. Do not touch
the cable before it has been discon-
nected from the power supply. Risk of
electric shock!
• If the replacement of the supply cord is
necessary, this has to be done by the
manufacturer or his agent in order to
avoid a safety hazard.
• Only use grinding discs where the in-
dicated rotational speed is at least as
high as what has been specified on the
name plate of the device.
• Carry out a visual inspection of the
grinding disc before use. Do not use
any damaged or deformed grinding
discs. Replace any damaged or worn
grinding discs.
• Make sure that the sparks produced by
grinding do not present a danger, e.g.
reach people or ignite flammable subs-
tances.
• Always wear safety goggles, safety
gloves, respiratory protection and ear
protection when grinding, brushing and
cutting.
• Never keep the fingers between the
grinding disc and spark protection or in
close proximity to the protective hoods.
There is a risk of crushing.
• The rotating parts of the device cannot
be covered due to functional reasons.
Therefore, proceed cautiously and hold
the workpiece firmly in order to avoid
slipping which could cause your hands to
come into contact with the grinding disc.
• The workpiece gets hot during grinding.
Do not touch the machined area, allow
it to cool down. There is a risk of bur-
ning. Do not use coolants or the like.
• If you are tired or have consumed al-
cohol or tablets, do not work with the
device. Always have a break on time.
• Switch the device off and remove the
mains plug
- to loosen a blocked insertion tool,
- if the connection line is damaged or
entangled,
- in case of unusual sounds.

RESIDUAL RISKS

Even if properly operating and handling this
electric tool, some residual risks will remain.
Due to its construction and build, this electric
tool may present the following hazards:
a) Lung damage if suitable respiratory
protection is not worn.
b) Hearing damage if suitable ear protec-
tion is not worn.
c) Damage to health due to
- touching the area of the grinding tool
which is not covered;
- ejection of parts of workpieces or
damaged grinding discs.
d) Health injuries which result from swin-
ging hand and arm, in the event that
the device is used over a longer period
of time or is not used and maintained
properly.
Warning! During operation, this
electric tool generates an electro-
magnetic field which, under certain
G B
M T
7 3