If the caller presses the 6 key, the message
"RECORD MESSAGE, PRESS # KEY TO BROADCAST
YOUR MESSAGE" prompts the caller to start speaking.
The message can be up to 90 seconds long. If the user
exceeds 90 second duration, the message will not play
back.
At any time during the call, the caller can enter the #
key or hang-up the phone to exit. Also, when a key input
is necessary, the caller has 5 seconds to enter a key or
the system hangs up automatically.
The password can be returned to the default
"12345678" by opening the cover of the Router and
setting switch SW1 position #4 to the "ON" position for
5 seconds with the power "ON".
Default is to all zones. Phone receiving is disabled
during message playback; therefore, subsequent calls
must wait for the current message to be completed
before another recording will take place.
Preset operation
The preset optos are a combination of edge and
level-tripped. If the system sees an active edge on
an opto, it will set the input and output relays for the
corresponding preset. The relays will remain set until the
Figure 1-4.
PRESET 1
FEDERAL
SIGNAL
CORPORATION
R
UNIVERSITY PARK, IL
U.S.A.
290A4120-04
PRESET 2
PRESET 3
PRESET 4
PRESET 5
PRESET 6
Figure 1-3.
input goes away.
Setting a Preset:
To set a preset, select the zones desired for
the preset by pressing and releasing the appropriate
zone button. The LED corresponding to that zone will
illuminate. Select the input source (Channel A or Channel
B) for that preset. Press and hold the appropriate preset
button until it begins to flash. The preset is now set.
To recall a preset simply select the preset by
pressing and releasing the associated preset button.
1-2. CHASSIS DESCRIPTION.
The Model AR2000-M is assembled in a black,
sprayed aluminum 3-piece housing approximately 17.5"
wide by 14.25" deep by 3.5" high. It is intended to be
rack mounted in a standard 19" rack mount cabinet.
The housing is held together with eighteen screws,
eight on the front panel, six on the rear panel and four
securing the top to the sides.
The main printed circuit board is attached to the
lower housing with seven screws. Separate wiring
harnesses connect the front and rear boards to the
main printed circuit board. The front panel switches are
designated as CH A, CH B, ALL CALL, CANCEL ZONE 1
through ZONE 8 and PRESET 1 through PRESET 8.
The Model AR2000-P is assembled in a black,
sprayed aluminum 3-piece housing approximately 17.5"
wide by 10.125" deep by 1.75" high. It is intended to be
rack mounted in a standard 19" rack mount cabinet. The
housing is held together with twelve screws, four on the
front panel, four on the rear panel and four securing the
top to the sides. The front panel switches are designated
as PRESET 1 through PRESET 8.
The Model AR2000-Z is assembled in a black,
sprayed aluminum 3-piece housing approximately 17.5"
wide by 10.125" deep by 1.75" high. It is intended to be
rack mounted in a standard 19" rack mount cabinet. The
housing is held together with twelve screws, four on the
front panel, four on the rear panel and four securing the
top to the sides. The front panel switches are designated
as ZONE 1 through ZONE 8.
-3-
PRESET 7
PRESET 8
POWER
290A4120-03