Dimensions And Specifications; Clearances; Gas Pressures; Gas Inlet Size - U.S. Range U24-4S Manual De Instalación Y Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DIMENSIONS AND SPECIFICATIONS

Clearances

Clearances Applicable For All Models
Surface
Combustible Wall Minimum
Non-Combustible Wall Minimum

Gas Pressures

Minimum Supply
Gas
Pressure
Natural
7" WC (17 .5 mbar)
Propane
11" WC (28 mbar)

Gas Inlet Size

Model Width
24" (610mm) &
36" (914mm)
48" (1219mm) &
60" (1524mm)

Individual Burner Input Rates

Burner
Open Top
Hot Top Burner (In lieu of 2 open top burners)
Griddle Burner (In lieu of 2 open top burners)
Raised Griddle Broiler (Consists of 3 burners)
Oven Burner Standard or Convection
Space Saver Oven
Rates are for installations up to 2000' (610m) above sea level
Page 4
Sides
14" (356mm)
6" (152mm)
0"
Manifold Operating
Pressure
4 .5" WC (11 .25 mbar)
10" WC (25 mbar)
Connection
3/4" NPT
Rear Gas Connection
1" NPT
Rear Gas Connection
Input BTU/HR
Natural
Gas
32,000
18,000
18,000
33,000
38,000
32,000
Rear
0"
Propane
Gas
26,000
18,000
18,000
33,000
32,000
28,000
Part # 4523341 Rev 2 (03/04/10)