SETTING OF THE STROKE
Choose the opening stroke (240 or 360 mm) by selecting it on the little switch, situated sidewise the
actuator. When the equipment was manufactured its stroke was of 240 mm.
It is suggested to do not use the 360 mm stroke for windows of which the max height is lower than
700 mm.
T e c h n i c a l D a t a
Pushing power
Pulling power
Stroke
(selectable at any time)
Supply voltage
Absorption
Absorbed power in charge
Traslation speed with no charge
Stroke lasting without charge
(360mm)
Double electrical insulating
Service typology
Operating temperature
Electrical devices protection level
Window fixing adjustment
Parallel connecting with
2 or more motors
End stroke
Equipment dimensions
Equipment weight
All data reported here are not binding and can be changed at any time without any notice
11
C 2 0 / 3 0
C 2 0 / 2 4
200 N
200 N
200 N
200 N
240 o 360 mm
230V-60Hz
24V c.c.
0,12 A
0,36 A
15 W
9 W
10 mm/s
9,7 mm/s
36 s
37 s
YES
Low voltage
S on 3 min.
S on 3 min.
-5 +50 C
IP 30
NO
YES
Electronic when opening
Amperometric absorption when closing
360x48x34
0,85 kg
C20/24
C20/24
24V
C20/230
CLOSED
BLACK
BROWN
(BLEU)
BLACK
LIGHT BLUE
BROWN
(RED)
OPEN
C20/230
BROWN
BLACK
(RED)
LIGHT BLUE
BROWN
C20/24
N
C20/230 Z39V-50Hz
L
CLOSED
OPEN
BLACK
(BLEU)