Description
Th e S 11000 is a stationary dust separator for the spot
extraction of air borne pollutants and cleaning. Most of
the dust is separated in the cyclone. Th e particles are col-
lected in the bottom of the cyclone and are automatically
emtied when the vacuum producter is shut down. Th e
fi nest particles are separated from the air by the internal
fi lter arrangement.
Th e fi ltercleaning in S 11000 and S 11000X is automati-
cally done with reverse pulse.
Technical Data
Dimensions and arrangements:
2012-01-18
Th e S 11000 fi lter unit is of modular construction. Th e
inlet module can for example be both rotated and rever-
sed. Additional module rings can be installed to increase
the storage capacity of the cyclone. Collected dust is
contained in a plastic sack or container.
Th e S 11000X is equipped with larger fi lter area and an
extra module ring.
Inlet
Outlet
Filter area
S 11000, S 11000E
S 11000X
Degree of separation DIN 24184/3
Max temp.
Filter Cleaning with Reverse Pulse (not S 11000E)
Compressed air
Connection, hose
El connection
Max Q
*
)
Note: Always consider fi lter loading.
PRESSURE LOSS
kPa
5
4
3
2
1
0
0
S 11000, S 11000X - 16
S 11000
Ø 108 mm
Ø 108 mm
8,4 m
12 m
99,9 %
130
4 l/s, 4 bar
6/8 mm
24 V AC, 1A
1000 m
Δ p
200
400
600
800
2
2
O
C
3
)
/h*
Q
m
3
/h
1000
Part No 9057