• After a dive (sea, lake, or pool), always rinse with fresh water and dry.
• Check the condition of the gaskets (O-rings) every time you open the body
of the torch.
• Clean and grease the parts involved in opening the torch with silicone
grease.
• Do not clean the torch with products that contain aggressive surfactants
(such as degreasers) or solvents to avoid damaging the product of sealing
gaskets.
• It is advisable to have your product inspected annually by an authorised
SEAC center.
FLOODING
If water gets into the torch, open the body, remove the batteries, and
immediately rinse the internal parts in fresh water. Then dry everything
with a cloth and a hair dryer using warm air, paying close attention to the
mechanical parts. Remove any oxide that may have formed on the metal
parts and conduct an operations test.
If a significant quantity of water has entered the torch and has remained
there for a long period, open the torch body and immediately rinse the
internal parts in fresh water. In this event we suggest that you immediately
contact a competent repair center or contact the closest SEAC shop.
WARRANTY CONDITIONS
SEAC guarantees the product two years from the time of purchase.
SEAC strongly recommends that you keep your sales receipt as evidence of
your date of purchase.
The warranty does not include parts subject to normal wear and tear:
• O-ring, batteries.
• This warranty does not cover damage resulting from:
• Mechanical blows.
• Use in excessively chlorinated or polluted water.
• Prolonged exposure to intense sources of heat above 70 °C.
Q5
15