WPL44/ WPL44NP   MasterCool® Mirage Window Evaporative Cooler 
Water Connection   
NOTE:  A standard sill cock with water valve 
attached (locally available) will be required to 
connect the water supply to the cooler. 
1. Steady water supply is required for operation of 
the cooler. If taking water from an external 
water faucet, install a sill cock and shutoff valve.  
2. Install plastic or copper line to sill cock and 
connect it to the float valve. 
Overflow Drain 
1.
Slide the rubber washer over the overflow fitting  
   
and push through the hole in the bottom of the 
   
cooler from the top side. 
2.
Secure the drain from beneath the pan  
with the Lock Nut. Make sure the rubber washer 
does not twist while tightening, which could cause  
it to leak.  DO NOT OVERTIGHTEN. 
3.
If leakage occurs after reservoir is full, retighten 
    
the overflow fitting until leaking stops. A small amount of 
 silicone caulk may be used if necessary. 
4.
Attach a drain hose to the bottom of the fitting  if necessary.  
Water Level 
Two inches of water should be maintained in the 
bottom of the cooler to ensure sufficient water 
for correct operation of the cooler.
The float is factory‐installed to maintain a 2 inch 
level of water, but may require adjustment if shipping 
or installation has caused the setting to shift.  
 
 
 
 
 
 
 
 
 
 
 
Water Pump
 
A self‐contained water pump continuously circulates water through the water 
distribution system and over the media. 
This pump is rated for 7500 CFM supplying more than adequate water pressure 
to saturate the media for cooling effectiveness. 
 
 
 
 
 