8. Routine maintenance plan

Perform the following operations and checks every 6 months according to intensity of use of the
automation.
Without 230 V~ power supply and batteries if present:
-
Lubricate the levers of the gearmotor.
-
Lubricate the rotation pivot of the gate leaf.
-
Lubricate the gate leaf hinges.
-
Check the good conditions of the electric connection.
-
Check that the fixing screws of the gearmotor are firmly tightened.
-
Clean the inside of the cases and check that drain is not clogged.
-
Check the value of the capacity of the motor condenser.
Reconnect the 230 V~ power supply and batteries if present:
-
Check the power adjustment.
-
Check the good operation of all command and safety functions (photocells).
-
Check the good operation of the release system.