Sensor OUTSPIDER PA and OUTSPIDER DT operation
The sensors can be connected in DIP/RELE' mode or in PC/BUS mode:
DIP/RELE' Mode (SW2:DIP1-ON):
The programming occurs via the two sets of dip-
switches which are on board:
In this working mode:
-
the relay and O.C. outputs are active
-
the RS485 derial is not active
-
the USB connexction is active
-
the HPWIN software only allows the
visualization (and not the programming)
of the detector status.
-
The connection of the detector occurs
exclusively using the relays and outputs on board.
PC mode and BUS activation (SW2: DIP1-OFF):
The programming can occur by PC via the HPWIN software or via
the Dip mode following a special procedure.
In the PC mode, although previously set in the detector by the
DIP-SWITCH, the configuration can be modified using the HPWIN
program.
In this working mode:
- The relay and O.C. outputs are active
- The RS485 serial is active
- The USB connection is active
- The HPWIN software allows the entire management of the detector
- The connection of the detector occurs by using the RS485 serial or the relays on board.
Only management of the LEDs and the AUX clamp cannot be modified through the
PC, but only using the related DIP SWITCHES (1 - 2 - 3 - 4 - 5 - 6 and 8 of the SW 2).
Acquisition sensor OUTSPIDER PA WS and OUTSPIDER DT WS
Follow the radio sensors acquisition procedure described in either the central stations or receiver
which the sensors will be coupled with.
For the sensor, set the desired radio frequency using dip switches 1 to 5 on the SW1 panel,
connect the battery and run a tamper transmission.
Trimmer for
SW 2
adjusting
microwave
capacity,
increases
when turned
clockwise
MW
GIALLO
ROSSO
- 47 -
USB-OUT module
Connector for connecting the module mod. USB-OUT (item 1135105) for
direct handling of the sensor by way of the PC.
With the USB-OUT adapter it is possible to connect the sensor
SW 1
directly to the PC for managing through the HPWIN software.
OUTSPIDER PA and OUTSPIDER DT
In the RELAY mode: through this connection it is possible
to display the configuration made by way of the DIP SWITCH,
display actual sensor operation and acquire the download of
ON
SW1
the last 1920 events to the pc.
1 2 3 4
5 6 7 8
ON
1 2 3 4
5 6 7 8
SW2
In BUS mode: through this connection it is possible to display
1.0
1.5
2.2
2.7
VERDE
USB
ATTENTION: in order to test the detector, it is
necessary to close the cover correctly. To maintain
the USB connection active, take the USB-OUT module cable from the lower
side of the detector beside the blocking screw of the cover
OUTSPIDER PA WS (UB) (U) and OUTSPIDER DT WS (UB) (U)
To connect the sensor to the PC you must enable the USB interface via the
dip 6 of SW1 before attaching the connecting cable between the PC and
the sensor.
Once dip 6 of SW1 is switched ON, wait about 10 seconds and then connect
the cable to the sensor and the PC.
When the USB interface is activated, the sensor has a constant
consumption of about 35 mA. Once you have finished working with
your PC, disconnect the USB cable and switch the dip 6 of SW1 to
OFF to set the sensor in normal operating, low consumption mode.
and modify the configuration, even is
previously completed by way of DIP
SW ITCH, adjust microwav e
sensitivity, display actual sensor
operation and acquire the
download of the last 1920 events
to the pc.