Electric Connections - Quick TSC Manual De Instalacion Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

INSTALLATION
GB

ELECTRIC CONNECTIONS

The TSC complies with EMC standards (electromagnetic compatibility) but requires correct installation to avoid
compromising its performance and that of the surronding instruments.
For this reason the TSC wires must be positioned at a distance of at least:
• 1 m away from cables that carry radio signals (except SSB radio transmitters).
• 2 m away from cables for SSB radio transmitter signals.
Follow the rules below to construct the electrical installation relative of the TSC:
• Connect the TSC connectors to the connectors coming from the TMS.
• Put in a switch, to turn on and shut off the TSC (not provided).
• Position the switch so that it is within easy reach should it be necessary to shut off the TSC in an emergency.
• Insert a 100mA quick-acting fuse on the command power supply line (not provided).
• Use wires, for the TSC power supply, with a correct cross section according to their length.
• Do not use supply from the motors or thrusters battery circuit for the TSC.
• Before switching on the power to the TSC, check that all the electrical connections are correct.
ELECTRICAL CONNECTIONS DIAGRAM
TCD 1042
TSC
TMS
RED
BLACK
RED
EXTENSION
FUSE
BLACK
MOTOR
SWITCH
SWITCH
FUSE
SPLITTER
FOR TCD (TCDSP)
EXTENSION
SPLITTER
FOR TMS (TMSSP)
FUSE
FUSE
*
*
TO THE SERVICES BATTERY
BATTERY
* Common negative for the battery groups.
10
TSC MAIN SWITCH COMMAND - REV001B

Publicidad

Tabla de contenido
loading

Tabla de contenido