8. be sure to remove and clean the screen filter located on the side panel on a monthly basis using lukewarm
water at around 77°F/25.0°C or with a neutral detergent solution. Dry the filter and reinstall it into its
original position. If proper ventilation is not maintained, dust will accumulate and eventually appliance
failure may follow, resulting expenses not covered under warranty.
Cleaning The Condenser
1. Slide out the side filter screen, using a screw driver remove the screw located at the bottom panel, then
remove the side panel to clean the condenser.
2. Use a vacuum cleaner or a soft brush to remove all dirt and build up from the condenser.
Sterilizing The Appliance
The appliance should be sterilized before operating. After sterilizing the appliance, DO NOT let it sit for an
extended period of time.
1. Wash your hands with anti-bacterial soap.
2. According to food safety regulations and manufacturer specifications, prepare five liters of warm
(113°F/45.0°C to 140°F/60.0°C), sterilizing solution consisting of a tablespoon of chloride condense
liquefaction or sodium chlorate diluted with two liters of water (100 ppm).
3. Soak all removable parts in the sterilizing solution for five minutes.
4. Place the sterilized parts on a clean and dry area for drying.
5. Wipe down all the surfaces of the appliance.
6. DO NOT spill any liquid on the cover of the motor that is located on the rear of the appliance.
Sterilizing The Chambers
The assembled chambers and its respective parts should be properly sterilized and thoroughly rinsed with
clean, cold water before use.
1. According to food safety regulations and manufacturer specification, prepare five liters of warm
(113°F/45.0°C to 140°F/60.0°C) sterilizing solution (remaining chloride 100 or bleach).
2. Fill the chamber with sterilizing solution.
3. Use nonabrasive brushes to wipe the surfaces projected above the solution level and the lower area of
the chamber immersed with the sterilizing solution.
4. Attach the chamber cover and operate the appliance to mix the sterilizing solution for about two
minutes. Drain the sterilizing solution from the chamber via the dispenser.
ENG-19