CARBON MONOXIDE POISONING MAY LEAD TO DEATH!
DANGER
– Risk of indoor air pollution and Carbon
Monoxide Poisoning. Use heater only in
well ventilated areas.
– Refer to Safety Information on pages 1-2
for information about Carbon Monoxide
Poisoning.
– ALWAYS provide a fresh air opening in the
heated space of at least three square feet
(2,800 sq. cm) for each 100,000 BTU / Hr.
of heater output. Provide a larger opening if
more heaters are being used.
Always disconnect the heater from the LP
cylinder before putting the heater into storage. If
for any reason the heater is to be stored indoors,
the tank MUST be disconnected from the LP
cylinder, and the cylinder stored outdoors in a
well-ventilated area, out of the reach of children,
and in accordance with the Standard for Storage
and Handling of Petroleum Gases, ANSI/NFPA
58 - latest edition and Natural Gas and Propane
Installation Code, CSA B149.1. The plastic valve
plug or valve cover supplied with the cylinder
must be re-installed on the valve to protect the
fitting from damage.
© 2015, Pinnacle Products International, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING,
CONNECTED TO A POWER SOURCE, OR WHILE
CONNECTED TO A FUEL SOURCE
Ventilation
non-adequately ventilated enclosed spaces.
Storage / Maintenance
any other gas or oil burning appliances.
NOTE: Installation and repair of this heater
should be done by a qualified service person.
ALWAYS be sure to follow proper maintenance
procedures. This should include cleaning the
inside of the heater once a month and checking
the spark gap at least once a heating season.
Re-gap the terminals to 0.195" (4.9 mm).
9
Minimum Ventilation Opening Needed
80V-LPC-B
2.4 ft.
2
2220 cm
2
Not for use in residential
DANGER
living areas or in
Never store an LP cylinder
DANGER
inside of a building or near
Convection Heater User's Manual
200V-LPC-B
6.0 ft.
2
5570 cm
2