MULTI AIR CONDITIONER SYSTEM
DEFINITION
Multi air conditioner systems save space by letting you connect multiple indoor units to a single outdoor unit.
• It is possible to operate the indoor units individually or simultaneously. The operation mode priority is given to the
fi rst unit that turned on.
• During operation, heating and cooling mode could not be activated at the same time for different indoor unit.
The power indicator blinks to indicate the indoor unit is standing by for different operation mode.
OPERATION CONDITION
OPERATION CONDITION
Multi Split Outdoor Unit
(CU-2E15LBE, CU-2E18LBE, CU-3E18LBE, CU-4E23LBE, CU-4E27CBPG)
Temperature (°C)
Max.
COOLING
Min.
Max.
HEATING
Min.
* DBT: Dry bulb temperature
* WBT: Wet bulb temperature
4
Room A
Room A
Outdoor
Indoor
CU-2E15LBE, CU-2E18LBE,
CU-4E27CBPG
*DBT
*WBT
*DBT
32
23
43
16
11
16
30
-
24
16
-
-10
INDOOR UNIT
INDOOR UNIT
Living room
Living room
Outdoor
CU-3E18LBE, CU-4E23LBE
*WBT
*DBT
26
46
11
-10
18
24
-11
-15
Outdoor Unit
Outdoor Unit
*WBT
26
-
18
-16