Panel heater cable
Phase = Brown
Neutral = Blue
Pilot Wire = Black
1.3.2.3 Wall mounted installation (Figure º)
- Place the device inclined on the brackets C and rotates the device
to place it on the brackets D. Lowering the device on the bracket. A
click indicates that the device is attached and locked. To unlock the
attachment tab, grab a screwdriver and push the tab (at the top left
of the attachment tab behind the device) towards the wall. Lift the
device while holding the tab with the screwdriver. Tilt it forward and
remove it from the supports C.
- To maintain performances of your unit, you should clean the upper
and lower grids of the unit about twice a year using a vacuum cleaner
or a brush.
Dirt may collect on the grids of the unit if the atmosphere is polluted.
This phenomenon is due to the poor quality of the ambient air. In this
case, it is recommended to check that the room is well ventilated
(ventilation, air inlet, etc.), and that the air is clean. The unit will not
be replaced under the guarantee because of this type of dirt. The
unit casing should be cleaned with a damp cloth, never use abrasive
products.
Mechanical Device (Figure ¾, refer to the table)
2.1
- For a temperature setting « Comfort », put
the switch E on I, adjust the control knob F
and wait for the temperature to stabilise.
- For the frost free mode, let the switch E on I, and adjust the control knob F on the minimum setting. The control knob allow to
maintain a temperature of about 7°C in the room when you are absent for a prolonged period (more than 24 hours).
12
Phase
Electricity
st
1
case: One heater
Neutral
grid
nd
2
case: Multiple heater
2. Maintenance
3. Utilisation
2 possible cases:
Unpiloted device
Pilot wire not connected
To devices with reception box
or central programming
E
Switch I/0
F
Control knob of the temperature