Mounting/Permanent Mounting
The unit is designed to be mounted into machinery/fixtures and is intended for continuous operation.
Upon mounting, make sure that
– only cold intake-air is supplied
– no heat back-up/accumulation occurs
– the unit is not subject to the hot-air jet of
another unit
– the unit is protected against mechanical
vibrations and shock.
Putting into Operation
Check the mains connection and the plug for mechanical defects!
Observe mains voltage: The mains voltage must agree with the data on the type plate of the unit. Extension cords
must have a cross section of at least 2 x 1.5 mm
Switching On:
Set the switch 9 to I. Adjust the air flow as required with the air slide 6. Adjust the temperature as required with the
potentiometer 8 (see reference values on the temperature scale 2 – only
utes.
Switching Off:
Turn the potentiometer 8 to the 0 position in order for the unit to cool down. When the unit has cooled down, set
the switch 9 to 0.
Operating Instructions
– Practical demonstrations of the applications are available free-of-charge at Leister Process Technologies as well
as through our after-sales service agents.
Maintenance, Service and Repairs
– Check mains connection and plug for interruption and mechanical damage.
– Before any work on the unit: Pull the mains plug.
– For secure and proper operation, keep the unit and the ventilation slots clean at all times.
– Use only original Leister accessories.
– When contaminated, clean the air filter 7 of the switched off unit using a brush. Replace a damaged or heavily
contaminated air filter.
–
The motor of the fan automatically switches off when the carbon brushes reach the minimum length. The oper-
A
ating lifetime of the carbon brushes is approx. 1600 hours. Have carbon brushes replaced through an author-
ized Leister after-sales service.
If the unit should fail despite the care taken in manufacturing and testing procedures, repair should be carried out
by an authorized Leister after-sales service agent.
Warranty
For this tool, we generally provide a guarantee in accordance with the statutory/country-specific regulations from
the date of purchase (verified by invoice or delivery document). Damage that has occurred will be corrected by
replacement or repair of the unit.
Additional claims shall be excluded, subject to statutory regulations.
Damage caused by normal wear, overloading or improper handling is excluded from the guarantee.
Guarantee claims will be rejected for tools that have been altered or changed by the purchaser.